During runntime of mwan3 we could add dynamicly networks to this ipset
which would then treated as connected networks by mwan3.
This is also usefull for ipsec.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
With the list param "rt_table_lookup" in the mwan3 section globals,
it is now possible to add a additional routing table numbers which would get
also parsed and will be added to the connected network.
So mwan3 will treat them as they are directly connected to this device.
This could be usefull if we use ipsec.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
The generation for reporting the policies uses the same code add a
common function to reduce duplication.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
Get downtime information for the tracked mwan3 wan interfaces.
The information shows how long this interface is in disconnected state.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
Get uptime information for the tracked mwan3 wan interfaces.
The information shows how long this interface is in connected state.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
If a interface is down, call ubus will return an null message which is
used to json_load, it causes json_get_vars gets value from last load and
l3_device various is nonzero.
Signed-off-by: Kyson Lok <kysonlok@gmail.com>
Move setting global enabled flag from /etc/init.d/mwan3 to mwan3
command. So we could start mwan3 from the cmd mwan3 as well.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
- The original copy process is to delete all routing tables first,
then add new routing table. This process is too slow and very dirty.
- We use grep to identify the changes and apply them.
- ignore ipv6 unreachable routes
- update version number
Signed-off-by: Chen Minqiang <ptpt52@gmail.com>
If an interface is not tracked by mwan3 or enabled and this interface is
setup by netifd, then the connected ipset is not update by mwan3.
To fix this also call connected ipset update code even if the interface
is not tracked or enabled by mwan3.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
Only execute an ifup event with the command "mwan3 ifup <iface>" if the
l3_device is found in the ubus "network.interface.<iface>".
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
The normal situation should be to use ping without quality_check.
If quality_check option is not set in the default option then ping
quality_check is not performed during tracking. This is and should
be the default situation.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
1. Test link quality based on packet loss & latency w.r.t. pre-defined high and low watermark values.
2. Extended ubus support to provide packet loss & latency information per wan per track_ip
Signed-off-by: Nishant Sharma <codemarauder@gmail.com>
To fix the shell local issue in the ubus mwan3 rpcd shell script, move
the switch case statment into a function.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
Considering that ipv6 NPT/NAT/NETMAP is done manually by user,
mwan3 can balance ipv6 interfaces as it does with ipv4.
Interface wan2 was renamed to wanb as wan2, wan3, ... will eventually
colide with OpenWrt with default wan6 interface when more than 6
interfaces are in use.
New interfaces, members for wan6 and wanb6 where created, both disabled
by default. Policies where adapted as well.
The option "family" is set respectively in each interface. When missing,
mwan3 assumes ipv4, that will fail when interface is IPv6 only.
Signed-off-by: Luiz Angelo Daros de Luca <luizluca@gmail.com>
Add missing globals config section with default values.
Without the correctly named section, mwan3 startup will fail with the error - Warning: mwan3 is global disabled. Usage: /etc/init.d/mwan3 start.
Compile: not required
Run tested: LEDE 17.01.04
Author-name: Rob White
Maintainer: Florian Eckert <fe@dev.tdt.de>
Signed-off-by: Rob White <rob@blue-wave.net>
The IPsec ip route table has the default number 220.
If mwan3 has more then 7 bits set (124 interfaces) then if mwan3 down is
executed the table is also cleared. To solve this set default max 7
bits in the mmx_mask for mwan3.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
Adjust the dependency from ip-full back to ip.
Returning back to "ip" is now possible as busybox does not provide
"ip" any more, making "ip" again reference to ip-tiny or ip-full.
Reference to discussion in #5747
Signed-off-by: Hannu Nyman <hannu.nyman@iki.fi>
We need always three of the firewall mask value for
* default routing table
* blackhole
* unreachable
the other will be used for the interfaces.
* If we have set the mmx_mask to max 0xFF00 (8 bit set) we could use max 252
interfaces.
* If we have set the mmx_mask to min 0x0E00 (3 bit set) we could use max 4
interfaces.
Only the ones are counting from the firewall mask value.
Minimal three firewall mask bit vaules must be set.
Maximal eight firewall mask bit vaules could be set.
Table overview mmx_mask value bits vs. max interfaces
mmx_mask value bits set 1 -> not usefull
mmx_mask value bits set 2 -> not usefull
mmx_mask value bits set 3 -> 4 Interfaces (mask example 0x0E)
mmx_mask value bits set 4 -> 12 Interfaces
mmx_mask value bits set 5 -> 28 Interfaces
mmx_mask value bits set 6 -> 60 Interfaces
mmx_mask value bits set 7 -> 124 Interfaces
mmx_mask value bits set 8 -> 252 Interfaces (mask example 0xFF)
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
Add a new ACTIONs:
* connected ACTION is called once if mwan3track reach all configured track_ips
* disconnected ACTION is called once if mwan3track is unable to reach the track_ips
The connected/disconnected will called only by mwan3track in opposite
the ACTIONs ifup/ifdown will also be called by netifd.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>