#!/bin/sh /etc/rc.common
|
|
|
|
START=60
|
|
USE_PROCD=1
|
|
UPSMON_C=/var/etc/nut/upsmon.conf
|
|
|
|
nut_upsmon_conf() {
|
|
local cfg="$1"
|
|
|
|
echo "# Config file automatically generated from UCI config" > $UPSMON_C
|
|
|
|
config_get runas "$cfg" runas "nut"
|
|
[ -n "$runas" ] && echo "RUN_AS_USER $runas" >> $UPSMON_C
|
|
|
|
config_get val "$cfg" minsupplies 1
|
|
echo "MINSUPPLIES $val" >> $UPSMON_C
|
|
|
|
config_get val "$cfg" shutdowncmd "/sbin/halt"
|
|
echo "SHUTDOWNCMD \"$val\"" >> $UPSMON_C
|
|
|
|
config_get val "$cfg" notifycmd
|
|
[ -n "$val" ] && echo "NOTIFYCMD \"$val\"" >> $UPSMON_C
|
|
|
|
config_get val "$cfg" pollfreq 5
|
|
echo "POLLFREQ $val" >> $UPSMON_C
|
|
|
|
config_get val "$cfg" pollfreqalert 5
|
|
echo "POLLFREQALERT $val" >> $UPSMON_C
|
|
|
|
config_get val "$cfg" hostsync 15
|
|
echo "HOSTSYNC $val" >> $UPSMON_C
|
|
|
|
config_get val "$cfg" deadtime 15
|
|
echo "DEADTIME $val" >> $UPSMON_C
|
|
|
|
config_get val "$cfg" powerdownflag /var/run/killpower
|
|
echo "POWERDOWNFLAG $val" >> $UPSMON_C
|
|
|
|
config_get val "$cfg" onlinemsg
|
|
[ -n "$val" ] && echo "NOTIFYMSG ONLINE \"$val\"" >> $UPSMON_C
|
|
config_get val "$cfg" onbattmsg
|
|
[ -n "$val" ] && echo "NOTIFYMSG ONBATT \"$val\"" >> $UPSMON_C
|
|
config_get val "$cfg" lowbattmsg
|
|
[ -n "$val" ] && echo "NOTIFYMSG LOWBATT \"$val\"" >> $UPSMON_C
|
|
config_get val "$cfg" fsdmsg
|
|
[ -n "$val" ] && echo "NOTIFYMSG FSD \"$val\"" >> $UPSMON_C
|
|
config_get val "$cfg" commokmsg
|
|
[ -n "$val" ] && echo "NOTIFYMSG COMMOK \"$val\"" >> $UPSMON_C
|
|
config_get val "$cfg" commbadmsg
|
|
[ -n "$val" ] && echo "NOTIFYMSG COMMBAD \"$val\"" >> $UPSMON_C
|
|
config_get val "$cfg" shutdownmsg
|
|
[ -n "$val" ] && echo "NOTIFYMSG SHUTDOWN \"$val\"" >> $UPSMON_C
|
|
config_get val "$cfg" replbattmsg
|
|
[ -n "$val" ] && echo "NOTIFYMSG REPLBATT \"$val\"" >> $UPSMON_C
|
|
config_get val "$cfg" nocommmsg
|
|
[ -n "$val" ] && echo "NOTIFYMSG NOCOMM \"$val\"" >> $UPSMON_C
|
|
config_get val "$cfg" noparentmsg
|
|
[ -n "$val" ] && echo "NOTIFYMSG NOPARENT \"$val\"" >> $UPSMON_C
|
|
|
|
notifylist() {
|
|
local value="$1"
|
|
append optval "$value" "+"
|
|
}
|
|
|
|
setnotify() {
|
|
local cfg="$1"
|
|
local optname="$2"
|
|
local optval
|
|
config_list_foreach "$cfg" "$optname" notifylist
|
|
if [ -z "$optval" ]; then
|
|
# If no list fallback to trying option, fallback to default
|
|
config_get optval "$cfg" "$optname" "$default"
|
|
if [ -n "$optval" ]; then
|
|
echo "$optval"
|
|
else
|
|
# No default, so do the NUT default
|
|
echo "SYSLOG"
|
|
fi
|
|
else
|
|
echo "$optval"
|
|
fi
|
|
}
|
|
|
|
local default optval
|
|
val=""
|
|
config_list_foreach "$cfg" defaultnotify notifylist
|
|
default="$optval"
|
|
echo "NOTIFYFLAG ONLINE $(setnotify "$cfg" onlinenotify)" >> $UPSMON_C
|
|
echo "NOTIFYFLAG ONBATT $(setnotify "$cfg" onbattnotify)" >> $UPSMON_C
|
|
echo "NOTIFYFLAG LOWBATT $(setnotify "$cfg" lowbatnotify)" >> $UPSMON_C
|
|
echo "NOTIFYFLAG FSD $(setnotify "$cfg" fsdnotify)" >> $UPSMON_C
|
|
echo "NOTIFYFLAG COMMOK $(setnotify "$cfg" commoknotify)" >> $UPSMON_C
|
|
echo "NOTIFYFLAG COMMBAD $(setnotify "$cfg" commbadnotify)" >> $UPSMON_C
|
|
echo "NOTIFYFLAG SHUTDOWN $(setnotify "$cfg" shutdownnotify)" >> $UPSMON_C
|
|
echo "NOTIFYFLAG REPLBATT $(setnotify "$cfg" repolbattnotify)" >> $UPSMON_C
|
|
echo "NOTIFYFLAG NOCOMM $(setnotify "$cfg" nocommnotify)" >> $UPSMON_C
|
|
echo "NOTIFYFLAG NOPARENT $(setnotify "$cfg" noparentnotify)" >> $UPSMON_C
|
|
|
|
config_get val "$cfg" rbwarntime 43200
|
|
echo "RBWARNTIME $val" >> $UPSMON_C
|
|
|
|
config_get val "$cfg" nocommwarntime 300
|
|
echo "NOCOMMWARNTIME $val" >> $UPSMON_C
|
|
|
|
config_get val "$cfg" finaldelay 5
|
|
echo "FINALDELAY $val" >> $UPSMON_C
|
|
|
|
config_get val "$cfg" certpath
|
|
if [ -n "$val" ]; then echo "CERTPATH $val" >> $UPSMON_C; fi
|
|
|
|
config_get_bool val "$cfg" certverify 0
|
|
if [ -n "$val" ]; then echo "CERTVERIFY $val" >> $UPSMON_C; fi
|
|
|
|
config_get_bool val "$cfg" forcessl 0
|
|
if [ -n "$val" ]; then echo "FORCESSL $val" >> $UPSMON_C; fi
|
|
}
|
|
|
|
nut_upsmon_add() {
|
|
local cfg="$1"
|
|
local type="$2"
|
|
local upsname
|
|
local hostname
|
|
local port
|
|
local powervalue
|
|
local username
|
|
local password
|
|
local system
|
|
|
|
# if UPSMON_C is a symlink we're only doing generated config
|
|
[ -L $UPSMON_C ] && {
|
|
rm -f $UPSMON_C
|
|
nut_upsmon_conf ""
|
|
}
|
|
|
|
config_get upsname "$cfg" upsname
|
|
config_get hostname "$cfg" hostname localhost
|
|
config_get port "$cfg" port
|
|
config_get powervalue "$cfg" powervalue 1
|
|
config_get username "$cfg" username
|
|
config_get password "$cfg" password
|
|
system="$upsname@$hostname"
|
|
if [ -n "$port" ]; then
|
|
system="$system:$port";
|
|
fi
|
|
echo "MONITOR $system $powervalue $username $password $type" >> $UPSMON_C
|
|
}
|
|
|
|
start_service() {
|
|
mkdir -p "$(dirname "$UPSMON_C")"
|
|
chmod 750 "$(dirname "$UPSMON_C")"
|
|
|
|
config_load nut_monitor
|
|
|
|
config_foreach nut_upsmon_conf upsmon
|
|
config_foreach nut_upsmon_add master master
|
|
config_foreach nut_upsmon_add slave slave
|
|
|
|
[ -z "$(cat /var/etc/nut/nut.conf)" ] && echo "MODE=netclient" >>/var/etc/nut/nut.conf
|
|
|
|
chmod 640 $UPSMON_C
|
|
chmod 640 /var/etc/nut/nut.conf
|
|
|
|
chown ${runas:-root}:$(id -gn ${runas:-root}) /var/etc/nut
|
|
chown ${runas:-root}:$(id -gn ${runas:-root}) /var/etc/nut/nut.conf
|
|
chown ${runas:-root}:$(id -gn ${runas:-root}) $UPSMON_C
|
|
|
|
[ -d /var/run/nut ] || {
|
|
mkdir -m 0750 -p /var/run/nut
|
|
chown ${runas:-root}:$(id -gn ${runas:-root}) /var/run/nut
|
|
}
|
|
|
|
exec $DEBUG /usr/sbin/upsmon $UPSMON_OPTIONS
|
|
}
|
|
|
|
stop_service() {
|
|
exec /usr/sbin/upsmon -c stop
|
|
}
|
|
|
|
reload_service() {
|
|
exec /usr/sbin/upsmon -c reload
|
|
}
|