Sometimes the return value of `ubus -S call network.interface.wan status`
cause `json_load` to return `Failed to parse message data` error.
To avoid this, the JSON data always should be quoted with double quotes.
Signed-off-by: Evren Yurtesen <eyurtese@abo.fi>
Removed quoatation marks from commit heading
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
Maintainer: Florian Eckert @feckert
Compile tested: not needed
Run tested: x86_64
Description:
Only two of the four IPs defined for wan are found in wanb, adding it so it is the same.
Signed-off-by: Daniel A. Maierhofer <git@damadmai.at>
With this change it is now possible to combine interface action events.
If an interface action is generated by netifd or mwan3 for example ifup,
ifdown, connectd or disconnected and this action is configured in the inteface
uci section, then the conntrack table is flushed by mwan3.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
This bug was introduced since dd206b7d0b
mwan3_remon_ipv4 and mwan3_remon_ipv6 is command to run not a variable
I add some comments on them hopefully people will notice it
Signed-off-by: Chen Minqiang <ptpt52@gmail.com>
Before this change two disconnected events were generated. This is wrong!
The disconnected event is impliciet generated by the hotplug script on ifdown
event. The mwan3track script is notified by a USR1 signal which
generates the disconnectd event. The additional "disconnectd" event on
ifdown is not required.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
Add to ubus the missing output information "policies" which could already
be observed with the command "mwan3 status".
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
If we set the option "local_source" in the globals mwan3 section to "none",
traffic generated by the router it self will always use the default route from
the wan interface with the lowest metric. If this interface is down
the router traffic still uses the connection with the lowest metric but
this is disconnected. Load balancing and failover from the lan site is
still possible. Only router generated traffic is not load balanced and
could not use failover.
To solve this issue with router initiated traffic add the additional
option "online_metric" to the mwan3 interface section.
If the interface is connected then this lower "online metric" is set in the
default routing table.
With this change we have at least a failover with router initiated
traffic.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
During runntime of mwan3 we could add dynamicly networks to this ipset
which would then treated as connected networks by mwan3.
This is also usefull for ipsec.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
With the list param "rt_table_lookup" in the mwan3 section globals,
it is now possible to add a additional routing table numbers which would get
also parsed and will be added to the connected network.
So mwan3 will treat them as they are directly connected to this device.
This could be usefull if we use ipsec.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
The generation for reporting the policies uses the same code add a
common function to reduce duplication.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
Get downtime information for the tracked mwan3 wan interfaces.
The information shows how long this interface is in disconnected state.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
Get uptime information for the tracked mwan3 wan interfaces.
The information shows how long this interface is in connected state.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
If a interface is down, call ubus will return an null message which is
used to json_load, it causes json_get_vars gets value from last load and
l3_device various is nonzero.
Signed-off-by: Kyson Lok <kysonlok@gmail.com>
Move setting global enabled flag from /etc/init.d/mwan3 to mwan3
command. So we could start mwan3 from the cmd mwan3 as well.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
- The original copy process is to delete all routing tables first,
then add new routing table. This process is too slow and very dirty.
- We use grep to identify the changes and apply them.
- ignore ipv6 unreachable routes
- update version number
Signed-off-by: Chen Minqiang <ptpt52@gmail.com>
If an interface is not tracked by mwan3 or enabled and this interface is
setup by netifd, then the connected ipset is not update by mwan3.
To fix this also call connected ipset update code even if the interface
is not tracked or enabled by mwan3.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
Only execute an ifup event with the command "mwan3 ifup <iface>" if the
l3_device is found in the ubus "network.interface.<iface>".
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
The normal situation should be to use ping without quality_check.
If quality_check option is not set in the default option then ping
quality_check is not performed during tracking. This is and should
be the default situation.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>