If we set the option "local_source" in the globals mwan3 section to "none",
traffic generated by the router it self will always use the default route from
the wan interface with the lowest metric. If this interface is down
the router traffic still uses the connection with the lowest metric but
this is disconnected. Load balancing and failover from the lan site is
still possible. Only router generated traffic is not load balanced and
could not use failover.
To solve this issue with router initiated traffic add the additional
option "online_metric" to the mwan3 interface section.
If the interface is connected then this lower "online metric" is set in the
default routing table.
With this change we have at least a failover with router initiated
traffic.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
Get downtime information for the tracked mwan3 wan interfaces.
The information shows how long this interface is in disconnected state.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
Get uptime information for the tracked mwan3 wan interfaces.
The information shows how long this interface is in connected state.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
If a interface is down, call ubus will return an null message which is
used to json_load, it causes json_get_vars gets value from last load and
l3_device various is nonzero.
Signed-off-by: Kyson Lok <kysonlok@gmail.com>
Move setting global enabled flag from /etc/init.d/mwan3 to mwan3
command. So we could start mwan3 from the cmd mwan3 as well.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
Only execute an ifup event with the command "mwan3 ifup <iface>" if the
l3_device is found in the ubus "network.interface.<iface>".
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
1. Test link quality based on packet loss & latency w.r.t. pre-defined high and low watermark values.
2. Extended ubus support to provide packet loss & latency information per wan per track_ip
Signed-off-by: Nishant Sharma <codemarauder@gmail.com>
To fix the shell local issue in the ubus mwan3 rpcd shell script, move
the switch case statment into a function.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
We need always three of the firewall mask value for
* default routing table
* blackhole
* unreachable
the other will be used for the interfaces.
* If we have set the mmx_mask to max 0xFF00 (8 bit set) we could use max 252
interfaces.
* If we have set the mmx_mask to min 0x0E00 (3 bit set) we could use max 4
interfaces.
Only the ones are counting from the firewall mask value.
Minimal three firewall mask bit vaules must be set.
Maximal eight firewall mask bit vaules could be set.
Table overview mmx_mask value bits vs. max interfaces
mmx_mask value bits set 1 -> not usefull
mmx_mask value bits set 2 -> not usefull
mmx_mask value bits set 3 -> 4 Interfaces (mask example 0x0E)
mmx_mask value bits set 4 -> 12 Interfaces
mmx_mask value bits set 5 -> 28 Interfaces
mmx_mask value bits set 6 -> 60 Interfaces
mmx_mask value bits set 7 -> 124 Interfaces
mmx_mask value bits set 8 -> 252 Interfaces (mask example 0xFF)
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
Add a new ACTIONs:
* connected ACTION is called once if mwan3track reach all configured track_ips
* disconnected ACTION is called once if mwan3track is unable to reach the track_ips
The connected/disconnected will called only by mwan3track in opposite
the ACTIONs ifup/ifdown will also be called by netifd.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
Move all shell commands which are executed during /lib/mwan3/mwan3.sh
sourceing into a seperate init function which must be called at first.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
In some situation it is not enough to send a SIGTERM to mwan3track to
ask service to stop accurate. If this does not work send him a SIGKILL
to prevent mwan3track running more then once per interface.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
If the date is changed by ntp the age value of mwan3 on ubus could jitter.
Use instead the uptime value from /proc/uptime which will not change during
system run.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
This commit fixed what 6d99b602 was supposed to fix without affecting
interface-bound traffic.
Before 6d99b602 interface-bound traffic was working normally as long
as at least one interface was online. However when the last interface
went offline, it was impossible to ping and such state was
unrecoverable.
Commit 6d99b602 fixed unrecoverable offline state problem (it was
possible to ping -I iface) but messed inteface-bound traffic. Traffic
with interface source address was not working if the interface was in
"offline" state, even if another interface was online.
The problem was caused by an inconsistent "offline" interface state:
iptables-related rules were kept while routing table and policy were
deleted.
The idea behind this commit is to:
1. Keep all the rules for each interface (iptables, routing table,
policy) regardless of its state. This ensures consistency,
2. Make interface state hotplug events affect only iptables'
mwan3_policy_* rules. Interface-related iptables, routing table
and policy is removed only when mwan3 is manually stopped.
To make such changes possible, it's necessary to change the way
mwan3_policy_* rule generator keeps track of interface state hotplug
events.
Until now, it checked for the existence of custom interface-related
routing table (table id 1, 2, 3, ...). Clearly we can no longer rely
on that so each interface state is stored explicitly in file.
Signed-off-by: Marcin Jurkowski <marcin1j@gmail.com>
If enough tracking ip are pinged skip the reset. They are not needed
anymore to mark the interface as up.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
Fixes the following bugs introduced in commit 815e83d4:
- hotplug: invalid parameter order when initial interface state is "online",
mwan3track expects initial state to be the third argument
- hotplug: missing source ip address when initial interface state is "offline"
- mwan3track: source ip address should be the fourth argument
Signed-off-by: Marcin Jurkowski <marcin1j@gmail.com>
To know how old the ubus output is, add an age parameter which indicats
how old the check informations on the interface are.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
Add new interface config option "inital_state".
If interface comeing up the first time(mwan3 start, boot),
there are now two option for interface behaviour:
- online (default as is now)
Set up interface regardless wether tracking ip are reachable or not.
- offline
Set up interface first to ping tracking ip and if they are reachable set up
the interface completely.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
Even though error was fixed the interface checks still fails, if last_resort
was set to blackhole or unreachable.
To fix this issue do not remove failure interface from iptables change on
down event.
Reported-by: Colby Whitney <colby.whitney@luxul.com>
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
If two interface have the same prefix "wan" for example "wan" and "wan1"
pgrep returns the PID for wan1 also "pgrep -f mwan3track wan".
Before this fix "wan1" was also killed! This is not what we want.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
Adds support for interface tracking using either ping, arping or
httping. This allows to track interface status on networks with filtered
ICMP traffic or simply to monitor data link layer etc.
To facilitate binding to a specified interface its IP address is passed
as a new mwan3track parameter. It's currently required by httping
and possibly by other tools that may be added in the future.
Signed-off-by: Marcin Jurkowski <marcin1j@gmail.com>
If mwan3track will not stop immediately after sending the kill signal,
the clean_up handler will delete the pid file later while the new mwan3track is
already running.
This could result in a situation that mwan3track is running
more then once because the old mwan3track service could not be killed,
because the pid file is missing.
Using pgrep to kill all mwan3track for the tracked interface and not using
pid file should fix this issue.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
If interface is getting down by netifd (unplug ethernet cable)
mwan3track will not recognize this change. It will also generate an
additional down event when he notice does his tracking interface is offline.
Mwan3track will now be informed by a signal (trap) USR1 during down event
that the interface is already down. An additional down event will not be
generated.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>