To know how old the ubus output is, add an age parameter which indicats
how old the check informations on the interface are.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
Add new interface config option "inital_state".
If interface comeing up the first time(mwan3 start, boot),
there are now two option for interface behaviour:
- online (default as is now)
Set up interface regardless wether tracking ip are reachable or not.
- offline
Set up interface first to ping tracking ip and if they are reachable set up
the interface completely.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
Even though error was fixed the interface checks still fails, if last_resort
was set to blackhole or unreachable.
To fix this issue do not remove failure interface from iptables change on
down event.
Reported-by: Colby Whitney <colby.whitney@luxul.com>
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
If two interface have the same prefix "wan" for example "wan" and "wan1"
pgrep returns the PID for wan1 also "pgrep -f mwan3track wan".
Before this fix "wan1" was also killed! This is not what we want.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
Adds support for interface tracking using either ping, arping or
httping. This allows to track interface status on networks with filtered
ICMP traffic or simply to monitor data link layer etc.
To facilitate binding to a specified interface its IP address is passed
as a new mwan3track parameter. It's currently required by httping
and possibly by other tools that may be added in the future.
Signed-off-by: Marcin Jurkowski <marcin1j@gmail.com>
If more then one interface get up/down at once mwan3 could be in a
undefined state, because more then one mwan3 hotplug script are running
and editing the iptables.
Lock the critical section should solve this issue.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
If mwan3track will not stop immediately after sending the kill signal,
the clean_up handler will delete the pid file later while the new mwan3track is
already running.
This could result in a situation that mwan3track is running
more then once because the old mwan3track service could not be killed,
because the pid file is missing.
Using pgrep to kill all mwan3track for the tracked interface and not using
pid file should fix this issue.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
If netifd set an interface up/down which is not tracked by mwan3 the
connected network of that interface should regardless be added/removed to the
mwan3_connected ipset.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
If interface is getting down by netifd (unplug ethernet cable)
mwan3track will not recognize this change. It will also generate an
additional down event when he notice does his tracking interface is offline.
Mwan3track will now be informed by a signal (trap) USR1 during down event
that the interface is already down. An additional down event will not be
generated.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
If mwan3track detects a failure the interval check will change to
"failure_interval" value until this interface is declared "offline".
After interface gets "offline" normal "interval" value is used again.
If interface ping is successful again "recovery_interval" value is used until
interface is declared "online" again.
Using the different intervals will accelerate the wan line detections on
failure and recovery.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
On interfaces with interface proto "qmi|ncm" and option dhcp
enabled the interface will be changed to $iface_4 | $iface_6. The
interface mapping in mwan3 will not recognize this interface. To fix
this issue an ubus call will check if an upper interface exists.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
User scripts conversion from luci-app-wan3 will be simplified if the variables
are passed by env instead of arguments.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
On dynamic interface proto (dhcp/pppoe) the hotplug will not execude (exit 9)
because the gateway is already released. The check will now only be made
on a ifup ACTION event.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
Local variable declarations outside of functions are illegal since the Busybox
update to v1.25.0, therfore remove them from the appropriate places.
Signed-off-by: Jo-Philipp Wich <jo@mein.io>
Fix iptables issue where a needed ipset was not created if first wan that came online was not a member of policy.
Signed-off-by: Jeroen Louwes <jeroen.louwes@gmail.com>
Fix issue with sticky sessions not working correctly
Fix issue where user created ipsets were not applied
Signed-off-by: Jeroen Louwes <jeroen.louwes@gmail.com>
Fixed issue in mwan3 status output with mwan3 interfaces not yet configuerd in network config
Removed nexthop argument as it is no longer used
Signed-off-by: Jeroen Louwes <jeroen.louwes@gmail.com>