Add to ubus the missing output information "policies" which could already
be observed with the command "mwan3 status".
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
If we set the option "local_source" in the globals mwan3 section to "none",
traffic generated by the router it self will always use the default route from
the wan interface with the lowest metric. If this interface is down
the router traffic still uses the connection with the lowest metric but
this is disconnected. Load balancing and failover from the lan site is
still possible. Only router generated traffic is not load balanced and
could not use failover.
To solve this issue with router initiated traffic add the additional
option "online_metric" to the mwan3 interface section.
If the interface is connected then this lower "online metric" is set in the
default routing table.
With this change we have at least a failover with router initiated
traffic.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
During runntime of mwan3 we could add dynamicly networks to this ipset
which would then treated as connected networks by mwan3.
This is also usefull for ipsec.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
With the list param "rt_table_lookup" in the mwan3 section globals,
it is now possible to add a additional routing table numbers which would get
also parsed and will be added to the connected network.
So mwan3 will treat them as they are directly connected to this device.
This could be usefull if we use ipsec.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
The generation for reporting the policies uses the same code add a
common function to reduce duplication.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
Get downtime information for the tracked mwan3 wan interfaces.
The information shows how long this interface is in disconnected state.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
Get uptime information for the tracked mwan3 wan interfaces.
The information shows how long this interface is in connected state.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
If a interface is down, call ubus will return an null message which is
used to json_load, it causes json_get_vars gets value from last load and
l3_device various is nonzero.
Signed-off-by: Kyson Lok <kysonlok@gmail.com>
Move setting global enabled flag from /etc/init.d/mwan3 to mwan3
command. So we could start mwan3 from the cmd mwan3 as well.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
- The original copy process is to delete all routing tables first,
then add new routing table. This process is too slow and very dirty.
- We use grep to identify the changes and apply them.
- ignore ipv6 unreachable routes
- update version number
Signed-off-by: Chen Minqiang <ptpt52@gmail.com>
If an interface is not tracked by mwan3 or enabled and this interface is
setup by netifd, then the connected ipset is not update by mwan3.
To fix this also call connected ipset update code even if the interface
is not tracked or enabled by mwan3.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
Only execute an ifup event with the command "mwan3 ifup <iface>" if the
l3_device is found in the ubus "network.interface.<iface>".
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
The normal situation should be to use ping without quality_check.
If quality_check option is not set in the default option then ping
quality_check is not performed during tracking. This is and should
be the default situation.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
1. Test link quality based on packet loss & latency w.r.t. pre-defined high and low watermark values.
2. Extended ubus support to provide packet loss & latency information per wan per track_ip
Signed-off-by: Nishant Sharma <codemarauder@gmail.com>
To fix the shell local issue in the ubus mwan3 rpcd shell script, move
the switch case statment into a function.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
Considering that ipv6 NPT/NAT/NETMAP is done manually by user,
mwan3 can balance ipv6 interfaces as it does with ipv4.
Interface wan2 was renamed to wanb as wan2, wan3, ... will eventually
colide with OpenWrt with default wan6 interface when more than 6
interfaces are in use.
New interfaces, members for wan6 and wanb6 where created, both disabled
by default. Policies where adapted as well.
The option "family" is set respectively in each interface. When missing,
mwan3 assumes ipv4, that will fail when interface is IPv6 only.
Signed-off-by: Luiz Angelo Daros de Luca <luizluca@gmail.com>
Add missing globals config section with default values.
Without the correctly named section, mwan3 startup will fail with the error - Warning: mwan3 is global disabled. Usage: /etc/init.d/mwan3 start.
Compile: not required
Run tested: LEDE 17.01.04
Author-name: Rob White
Maintainer: Florian Eckert <fe@dev.tdt.de>
Signed-off-by: Rob White <rob@blue-wave.net>
The IPsec ip route table has the default number 220.
If mwan3 has more then 7 bits set (124 interfaces) then if mwan3 down is
executed the table is also cleared. To solve this set default max 7
bits in the mmx_mask for mwan3.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>