diff --git a/AulaStud_fridge_compressor_timer_controller.ino b/AulaStud_fridge_compressor_timer_controller.ino index 2a87cbb..81ba60e 100644 --- a/AulaStud_fridge_compressor_timer_controller.ino +++ b/AulaStud_fridge_compressor_timer_controller.ino @@ -1,29 +1,54 @@ -int disable = 0; -int timer = 0; -int timerMAX = 900; //(countdown in seconds) -int fan = 0; -int relayPin = 0; -int fanPin = 1; +// Hi! Barb here: this is a quick and dirty implementation of a refrigeration compressor + evaporator fan(s) controller. +// I wrote this code to run it on an attiny45 that I was able to solder on the back of a 5V relay inside the refrigerator's +// control panel. This code relies on an external thermostat already doing its work and is not meant to manage internal +// temperature. It is written to make sure the compressor can get a minimum rest-time between cycles as to not overheat. +// This relay and attiny are connected in series with the main thermost's relay, so that they only function when it's calling. +// With this in mind, we assume the thermostat has just called for cooling every time the attiny is booted and leave the +// compressor running. After a set period of s (timerMAX) the compressor is switched off. +// In order to aid thermal transfer and maximize COP while using butane as refrigerant, the system needs to have a higher +// average temperature. Due to this reason, a fan is fitted between the fridge and freezer compartments to move air between +// the two. The fan is turned on after fanStartDelay to prevent rapid heating of the freezer and turned back on when the +// timer hits fanStopAdvance to allow for further freezer sub-cooling. + +// Last updated: 05/03/24 + +bool disable = 0; // bool to store compressor disable status +int timer = 0; // active countdown timer, between timerMax and 0 +const int timerMAX = 1500; // (countdown in seconds) +int relayPin = 0; // compressor relay output pin (active LOW) +int fanPin = 1; // fan MOSFET output pin (active HIGH) +const int fanStartDelay = 60; // fan turn-on delay in seconds +const int fanStopAdvance = 30; // fan turn-off advance in seconds (before the compressor stops, allows to sub-cool the freezer) void setup() { // put your setup code here, to run once: + + // firstly, we initialize the needed outputs pinMode(relayPin, OUTPUT); pinMode(fanPin, OUTPUT); + // then we set them low to keep the compressor on and the fans off at boot digitalWrite(relayPin, LOW); digitalWrite(fanPin, LOW); + // lastly, we set the timer at maximum so that the loop starts counting down timer = timerMAX; } void loop() { // put your main code here, to run repeatedly: + // fan control logic: // only enable fans after the compressor has been running for a while - if (timer < (timerMAX*4/5) && disable == 0) { + if (timer == (timerMAX - fanStartDelay) && disable == 0) { + // enable fan(s) after set delay if the compressor is not disabled digitalWrite(fanPin, HIGH); } - else if (timer == timerMAX) { + else if (timer == fanStopAdvance && disable == 0) { + // disable when we are about to stop the compressor digitalWrite(fanPin, LOW); } + else { + // do nothing + } // compressor control logic if (timer > 0 && disable == 0) { @@ -32,7 +57,7 @@ void loop() { } else if (timer > 0 && disable == 1) { - // when compressor is off, countdown moves at 5s/cycle + // when compressor is off, countdown moves at (1/5)s/cycle (5 times faster!) timer = timer - 5; } @@ -40,7 +65,7 @@ void loop() { // reset countdown timer to max once 0 is reached timer = timerMAX; - // realy control logic: warning! LOW = active! + // relay control logic: warning! LOW = active! if (disable == 0) { disable = 1; digitalWrite(relayPin, HIGH); @@ -51,10 +76,14 @@ void loop() { } } - else { //protect against underflow or bitflip + else { + // protect against underflow or bitflip: if no condition applies, reset to safe values timer = 0; - disable = 1; + disable = 0; + digitalWrite(fanPin, LOW); } - + + // now wait 1s so that we can roughly count time using the timer variable + // this is a stopping delay, kinda bad, but we don't have any inputs, hence it shouldn't matter! delay(1000); } diff --git a/AulaStud_fridge_compressor_timer_controller.ino.tiny8.hex b/AulaStud_fridge_compressor_timer_controller.ino.tiny8.hex new file mode 100644 index 0000000..8ac3698 --- /dev/null +++ b/AulaStud_fridge_compressor_timer_controller.ino.tiny8.hex @@ -0,0 +1,53 @@ +:1000000023C032C031C030C02FC0ACC02DC02CC006 +:100010002BC02AC029C028C027C026C025C0010285 +:100020000000040000000000000000003800000094 +:100030000000370002020202020202020202010272 +:10004000040810202004100811241FBECFE5D1E0C1 +:10005000DEBFCDBF20E0A0E6B0E001C01D92AC360F +:10006000B207E1F7C9D065C1CBCF90E0FC01E25CFB +:10007000FF4F24918C5C9F4FFC018491882399F061 +:1000800090E0880F991FFC01E25DFF4FA591B491AC +:10009000FC01E85DFF4F859194918FB7F894EC9146 +:1000A000E22BEC938FBF089590E0FC01E25EFF4FDE +:1000B0003491FC01E25CFF4F2491FC01EC5CFF4FAA +:1000C000E491EE23B9F0332329F0323001F198F4B2 +:1000D0003130C9F0F0E0EE0FFF1FE85DFF4FA59152 +:1000E000B4918FB7F894EC91611114C020952E2330 +:1000F0002C938FBF0895333011F0343059F78CB5FD +:100100008F7D8CBDE7CF8AB58F778ABDE3CF8AB567 +:100110008F7DFBCF2E2BECCF3FB7F89480916500FD +:1001200090916600A0916700B091680022B708B670 +:1001300001FE05C02F3F19F00196A11DB11D3FBF63 +:10014000BA2FA92F982F8827BC01CD01620F711DEE +:10015000811D911D46E0660F771F881F991F4A95E4 +:10016000D1F708951F920F920FB60F9211242F937B +:100170003F938F939F93AF93BF9380916100909132 +:100180006200A0916300B09164003091600020E3B0 +:10019000230F2D3758F54096A11DB11D2093600007 +:1001A0008093610090936200A0936300B093640019 +:1001B0008091650090916600A0916700B091680001 +:1001C0000196A11DB11D8093650090936600A093D8 +:1001D0006700B0936800BF91AF919F918F913F915D +:1001E0002F910F900FBE0F901F90189523EB230FA8 +:1001F0004196A11DB11DD2CF78948AB582608ABD87 +:100200008AB581608ABD83B7826083BF83B781600E +:1002100083BF89B7826089BF80B7826080BF329810 +:10022000319A309A379A8CB580648CBD80E01DDF9E +:1002300081E01BDF60E080E037DF60E081E034DFF9 +:100240008CED95E090936B0080936A0000E010E0E5 +:100250009CEDE92E95E0F92EC0916A00D0916B00DB +:10026000C03A25E0D207B1F58091690061E08823AA +:10027000C9F18091690081114DC02197D0936B0025 +:10028000C0936A0049DF4B015C0188EE482E83E091 +:10029000582E612C712C40DF681979098A099B0955 +:1002A000683E734081059105B0F381E0481A51081A +:1002B0006108710828EE820E23E0921EA11CB11C79 +:1002C000411451046104710431F70115110521F243 +:1002D00097DEC2CFCE31D10541F480916900811102 +:1002E000C8CF60E081E0E0DEC4CF1C161D060CF430 +:1002F000C0CFCD2BA9F4F0926B00E0926A00809100 +:100300006900811109C081E08093690061E080E0AB +:10031000CBDEB8CF2597B2CF1092690060E0F7CF5F +:1003200010926B0010926A001092690060E081E008 +:06033000EFCFF894FFCFAF +:00000001FF diff --git a/README.md b/README.md index f636a6c..1042058 100644 --- a/README.md +++ b/README.md @@ -1,3 +1,7 @@ -Controller basato su attiny45, un relé e un FET per il frigorifero usato che abbiamo preso per l'aulastud nel '23. +Controller basato su attiny45 (bootloader flashato a 1 MHz), un relé e un FET per il frigorifero usato che abbiamo preso per l'aulastud nel '23. Abbiamo dovuto sostituire il termostato e il design dell'evaporatore (parte fredda della serpentina) fa sì che ci sia rischio di trasporto di olio dal compressore e che si intasi il sistema se il compressore lavora per troppi minuti di fila (tipicamente dopo 30 minuti, a quel punto tocca staccare il frigo, riscaldarlo con un phon per sturare il blocco di olio, di solito nel reparto freezer, e poi riaccenderlo). -Questo controller è montato DOPO il termostato, in modo da impostare dei limiti di tempo massimo di accensione (15') e minimo di stand-by (3') del compressore. Inoltre, si occupa di accendere delle ventole nel compartimento freezer e frigo che aumentano il COP e permettono la completa evaporazione del refrigerante (butano). \ No newline at end of file +Questo controller è montato DOPO il termostato, in modo da impostare dei limiti di tempo massimo di accensione (15') e minimo di stand-by (3') del compressore. Inoltre, si occupa di accendere delle ventole nel compartimento freezer e frigo che aumentano il COP e permettono la completa evaporazione del refrigerante (butano). + +UPDATE 03/'24: +Ho aggiunto un delay di 60s all'accensione delle ventole per permettere al freezer di pre-raffreddarsi e poi uno spegnimento delle stesse 30s prima del compressore per far calare ulteriormente la temperatura nel comparto freezer. +Ho aumentato il tempo totale di accensione a 1500s (25'), portando il tempo di spegnimento forzato a 1/5 (5' con l'impostazione corrente) \ No newline at end of file