#!/bin/sh /etc/rc.common
START=60
USE_PROCD=1
UPSMON_C=/var/etc/nut/upsmon.conf
nut_upsmon_conf() {
local cfg="$1"
echo "# Config file automatically generated from UCI config" > $UPSMON_C
config_get runas "$cfg" runas "nut"
[ -n "$runas" ] && echo "RUN_AS_USER $runas" >> $UPSMON_C
config_get val "$cfg" minsupplies 1
echo "MINSUPPLIES $val" >> $UPSMON_C
config_get val "$cfg" shutdowncmd "/sbin/halt"
echo "SHUTDOWNCMD \"$val\"" >> $UPSMON_C
config_get val "$cfg" notifycmd
[ -n "$val" ] && echo "NOTIFYCMD \"$val\"" >> $UPSMON_C
config_get val "$cfg" pollfreq 5
echo "POLLFREQ $val" >> $UPSMON_C
config_get val "$cfg" pollfreqalert 5
echo "POLLFREQALERT $val" >> $UPSMON_C
config_get val "$cfg" hostsync 15
echo "HOSTSYNC $val" >> $UPSMON_C
config_get val "$cfg" deadtime 15
echo "DEADTIME $val" >> $UPSMON_C
config_get val "$cfg" powerdownflag /var/run/killpower
echo "POWERDOWNFLAG $val" >> $UPSMON_C
config_get val "$cfg" onlinemsg
[ -n "$val" ] && echo "NOTIFYMSG ONLINE \"$val\"" >> $UPSMON_C
config_get val "$cfg" onbattmsg
[ -n "$val" ] && echo "NOTIFYMSG ONBATT \"$val\"" >> $UPSMON_C
config_get val "$cfg" lowbattmsg
[ -n "$val" ] && echo "NOTIFYMSG LOWBATT \"$val\"" >> $UPSMON_C
config_get val "$cfg" fsdmsg
[ -n "$val" ] && echo "NOTIFYMSG FSD \"$val\"" >> $UPSMON_C
config_get val "$cfg" commokmsg
[ -n "$val" ] && echo "NOTIFYMSG COMMOK \"$val\"" >> $UPSMON_C
config_get val "$cfg" commbadmsg
[ -n "$val" ] && echo "NOTIFYMSG COMMBAD \"$val\"" >> $UPSMON_C
config_get val "$cfg" shutdownmsg
[ -n "$val" ] && echo "NOTIFYMSG SHUTDOWN \"$val\"" >> $UPSMON_C
config_get val "$cfg" replbattmsg
[ -n "$val" ] && echo "NOTIFYMSG REPLBATT \"$val\"" >> $UPSMON_C
config_get val "$cfg" nocommmsg
[ -n "$val" ] && echo "NOTIFYMSG NOCOMM \"$val\"" >> $UPSMON_C
config_get val "$cfg" noparentmsg
[ -n "$val" ] && echo "NOTIFYMSG NOPARENT \"$val\"" >> $UPSMON_C
notifylist() {
local value="$1"
append optval "$value" "+"
}
setnotify() {
local cfg="$1"
local optname="$2"
local optval
config_list_foreach "$cfg" "$optname" notifylist
if [ -z "$optval" ]; then
# If no list fallback to trying option, fallback to default
config_get optval "$cfg" "$optname" "$default"
if [ -n "$optval" ]; then
echo "$optval"
else
# No default, so do the NUT default
echo "SYSLOG"
fi
else
echo "$optval"
fi
}
local default optval
val=""
config_list_foreach "$cfg" defaultnotify notifylist
default="$optval"
echo "NOTIFYFLAG ONLINE $(setnotify "$cfg" onlinenotify)" >> $UPSMON_C
echo "NOTIFYFLAG ONBATT $(setnotify "$cfg" onbattnotify)" >> $UPSMON_C
echo "NOTIFYFLAG LOWBATT $(setnotify "$cfg" lowbatnotify)" >> $UPSMON_C
echo "NOTIFYFLAG FSD $(setnotify "$cfg" fsdnotify)" >> $UPSMON_C
echo "NOTIFYFLAG COMMOK $(setnotify "$cfg" commoknotify)" >> $UPSMON_C
echo "NOTIFYFLAG COMMBAD $(setnotify "$cfg" commbadnotify)" >> $UPSMON_C
echo "NOTIFYFLAG SHUTDOWN $(setnotify "$cfg" shutdownnotify)" >> $UPSMON_C
echo "NOTIFYFLAG REPLBATT $(setnotify "$cfg" repolbattnotify)" >> $UPSMON_C
echo "NOTIFYFLAG NOCOMM $(setnotify "$cfg" nocommnotify)" >> $UPSMON_C
echo "NOTIFYFLAG NOPARENT $(setnotify "$cfg" noparentnotify)" >> $UPSMON_C
config_get val "$cfg" rbwarntime 43200
echo "RBWARNTIME $val" >> $UPSMON_C
config_get val "$cfg" nocommwarntime 300
echo "NOCOMMWARNTIME $val" >> $UPSMON_C
config_get val "$cfg" finaldelay 5
echo "FINALDELAY $val" >> $UPSMON_C
config_get val "$cfg" certpath
if [ -n "$val" ]; then echo "CERTPATH $val" >> $UPSMON_C; fi
config_get_bool val "$cfg" certverify 0
if [ -n "$val" ]; then echo "CERTVERIFY $val" >> $UPSMON_C; fi
config_get_bool val "$cfg" forcessl 0
if [ -n "$val" ]; then echo "FORCESSL $val" >> $UPSMON_C; fi
}
nut_upsmon_add() {
local cfg="$1"
local type="$2"
local upsname
local hostname
local port
local powervalue
local username
local password
local system
# If no core config, use defaults
[ -r $UPSMON_C ] || nut_upsmon_conf ""
config_get upsname "$cfg" upsname
config_get hostname "$cfg" hostname localhost
config_get port "$cfg" port
config_get powervalue "$cfg" powervalue 1
config_get username "$cfg" username
config_get password "$cfg" password
system="$upsname@$hostname"
if [ -n "$port" ]; then
system="$system:$port";
fi
echo "MONITOR $system $powervalue $username $password $type" >> $UPSMON_C
}
start_service() {
rm -f $UPSMON_C
config_load nut_monitor
config_foreach nut_upsmon_conf upsmon
config_foreach nut_upsmon_add master master
config_foreach nut_upsmon_add slave slave
[ -z "$(cat /var/etc/nut/nut.conf)" ] && echo "MODE=netclient" >>/var/etc/nut/nut.conf
chmod 640 $UPSMON_C
chmod 640 /var/etc/nut/nut.conf
[ -d /var/run/nut ] || {
mkdir -m 0750 -p /var/run/nut
chown ${runas:-root}:$(id -gn ${runas:-root}) /var/run/nut
}
chown ${runas:-root}:$(id -gn ${runas:-root}) $UPSMON_C
$DEBUG /usr/sbin/upsmon $UPSMON_OPTIONS
}
stop_service() {
[ -r $PID_F ] && /usr/sbin/upsmon -c stop
rm -f $UPSMON_C
}
reload_service() {
upsmon -c reload
}