#!/bin/sh /etc/rc.common
|
|
|
|
START=82
|
|
STOP=28
|
|
USE_PROCD=1
|
|
UPSMON_C=/var/etc/nut/upsmon.conf
|
|
|
|
nut_upsmon_conf() {
|
|
local cfg="$1"
|
|
local RUNAS val optval
|
|
|
|
echo "# Config file automatically generated from UCI config" > "$UPSMON_C"
|
|
|
|
config_get RUNAS "$cfg" runas "nutmon"
|
|
[ -n "$RUNAS" ] && echo "RUN_AS_USER $RUNAS" >> "$UPSMON_C"
|
|
runas="$RUNAS"
|
|
|
|
config_get val "$cfg" minsupplies 1
|
|
echo "MINSUPPLIES $val" >> "$UPSMON_C"
|
|
|
|
config_get val "$cfg" shutdowncmd "/usr/sbin/nutshutdown"
|
|
echo "SHUTDOWNCMD \"$val\"" >> "$UPSMON_C"
|
|
|
|
config_get val "$cfg" notifycmd
|
|
[ -n "$val" ] && echo "NOTIFYCMD \"$val\"" >> "$UPSMON_C"
|
|
|
|
config_get val "$cfg" pollfreq 5
|
|
echo "POLLFREQ $val" >> "$UPSMON_C"
|
|
|
|
config_get val "$cfg" pollfreqalert 5
|
|
echo "POLLFREQALERT $val" >> "$UPSMON_C"
|
|
|
|
config_get val "$cfg" hostsync 15
|
|
echo "HOSTSYNC $val" >> "$UPSMON_C"
|
|
|
|
config_get val "$cfg" deadtime 15
|
|
echo "DEADTIME $val" >> "$UPSMON_C"
|
|
|
|
echo "POWERDOWNFLAG /var/run/killpower" >> "$UPSMON_C"
|
|
|
|
config_get val "$cfg" onlinemsg
|
|
[ -n "$val" ] && echo "NOTIFYMSG ONLINE \"$val\"" >> "$UPSMON_C"
|
|
config_get val "$cfg" onbattmsg
|
|
[ -n "$val" ] && echo "NOTIFYMSG ONBATT \"$val\"" >> "$UPSMON_C"
|
|
config_get val "$cfg" lowbattmsg
|
|
[ -n "$val" ] && echo "NOTIFYMSG LOWBATT \"$val\"" >> "$UPSMON_C"
|
|
config_get val "$cfg" fsdmsg
|
|
[ -n "$val" ] && echo "NOTIFYMSG FSD \"$val\"" >> "$UPSMON_C"
|
|
config_get val "$cfg" commokmsg
|
|
[ -n "$val" ] && echo "NOTIFYMSG COMMOK \"$val\"" >> "$UPSMON_C"
|
|
config_get val "$cfg" commbadmsg
|
|
[ -n "$val" ] && echo "NOTIFYMSG COMMBAD \"$val\"" >> "$UPSMON_C"
|
|
config_get val "$cfg" shutdownmsg
|
|
[ -n "$val" ] && echo "NOTIFYMSG SHUTDOWN \"$val\"" >> "$UPSMON_C"
|
|
config_get val "$cfg" replbattmsg
|
|
[ -n "$val" ] && echo "NOTIFYMSG REPLBATT \"$val\"" >> "$UPSMON_C"
|
|
config_get val "$cfg" nocommmsg
|
|
[ -n "$val" ] && echo "NOTIFYMSG NOCOMM \"$val\"" >> "$UPSMON_C"
|
|
config_get val "$cfg" noparentmsg
|
|
[ -n "$val" ] && echo "NOTIFYMSG NOPARENT \"$val\"" >> "$UPSMON_C"
|
|
|
|
notifylist() {
|
|
local value="$1"
|
|
append optval "$value" "+"
|
|
}
|
|
|
|
setnotify() {
|
|
local cfg="$1"
|
|
local optname="$2"
|
|
local optval
|
|
config_list_foreach "$cfg" "$optname" notifylist
|
|
if [ -z "$optval" ]; then
|
|
# If no list fallback to trying option, fallback to default
|
|
config_get optval "$cfg" "$optname" "$default"
|
|
if [ -n "$optval" ]; then
|
|
echo "$optval"
|
|
else
|
|
# No default, so do the NUT default
|
|
echo "SYSLOG"
|
|
fi
|
|
else
|
|
echo "$optval"
|
|
fi
|
|
}
|
|
|
|
local default optval
|
|
val=""
|
|
config_list_foreach "$cfg" defaultnotify notifylist
|
|
default="$optval"
|
|
{
|
|
echo "NOTIFYFLAG ONLINE $(setnotify "$cfg" onlinenotify)" ; \
|
|
echo "NOTIFYFLAG ONBATT $(setnotify "$cfg" onbattnotify)" ; \
|
|
echo "NOTIFYFLAG LOWBATT $(setnotify "$cfg" lowbatnotify)" ; \
|
|
echo "NOTIFYFLAG FSD $(setnotify "$cfg" fsdnotify)" ; \
|
|
echo "NOTIFYFLAG COMMOK $(setnotify "$cfg" commoknotify)" ; \
|
|
echo "NOTIFYFLAG COMMBAD $(setnotify "$cfg" commbadnotify)" ; \
|
|
echo "NOTIFYFLAG SHUTDOWN $(setnotify "$cfg" shutdownnotify)" ; \
|
|
echo "NOTIFYFLAG REPLBATT $(setnotify "$cfg" replbattnotify)" ; \
|
|
echo "NOTIFYFLAG NOCOMM $(setnotify "$cfg" nocommnotify)" ; \
|
|
echo "NOTIFYFLAG NOPARENT $(setnotify "$cfg" noparentnotify)" ; \
|
|
} >> "$UPSMON_C"
|
|
|
|
config_get val "$cfg" rbwarntime 43200
|
|
echo "RBWARNTIME $val" >> "$UPSMON_C"
|
|
|
|
config_get val "$cfg" nocommwarntime 300
|
|
echo "NOCOMMWARNTIME $val" >> "$UPSMON_C"
|
|
|
|
config_get val "$cfg" finaldelay 5
|
|
echo "FINALDELAY $val" >> "$UPSMON_C"
|
|
|
|
config_get val "$cfg" certpath
|
|
if [ -n "$val" ]; then echo "CERTPATH $val" >> "$UPSMON_C"; fi
|
|
|
|
config_get_bool val "$cfg" certverify 0
|
|
if [ -n "$val" ]; then echo "CERTVERIFY $val" >> "$UPSMON_C"; fi
|
|
|
|
config_get_bool val "$cfg" forcessl 0
|
|
if [ -n "$val" ]; then echo "FORCESSL $val" >> "$UPSMON_C"; fi
|
|
|
|
havemon=1
|
|
}
|
|
|
|
nut_upsmon_add() {
|
|
local cfg="$1"
|
|
local type="$2"
|
|
local upsname
|
|
local hostname
|
|
local port
|
|
local powervalue
|
|
local username
|
|
local password
|
|
local system
|
|
|
|
config_get upsname "$cfg" upsname
|
|
config_get hostname "$cfg" hostname localhost
|
|
config_get port "$cfg" port
|
|
config_get powervalue "$cfg" powervalue 1
|
|
config_get username "$cfg" username
|
|
config_get password "$cfg" password
|
|
system="$upsname@$hostname"
|
|
if [ -n "$port" ]; then
|
|
system="$system:$port";
|
|
fi
|
|
echo "MONITOR $system $powervalue $username $password $type" >> "$UPSMON_C"
|
|
|
|
havems=1
|
|
}
|
|
|
|
build_config() {
|
|
mkdir -m 0750 -p "$(dirname "$UPSMON_C")"
|
|
|
|
config_load nut_monitor
|
|
config_foreach nut_upsmon_conf upsmon
|
|
config_foreach nut_upsmon_add master master
|
|
config_foreach nut_upsmon_add slave slave
|
|
|
|
[ ! -s /var/etc/nut/nut.conf ] && {
|
|
echo "MODE=netclient" >>/var/etc/nut/nut.conf
|
|
chmod 640 /var/etc/nut/nut.conf
|
|
chgrp "$(id -gn "${runas:-nutmon}")" /var/etc/nut/nut.conf
|
|
}
|
|
|
|
[ -s "$UPSMON_C" ] && chmod 640 "$UPSMON_C"
|
|
[ -s "$UPSMON_C" ] && chgrp "$(id -gn "${runas:-nutmon}")" "$UPSMON_C"
|
|
}
|
|
|
|
interface_triggers() {
|
|
local action="$1"
|
|
local triggerlist trigger
|
|
|
|
config_get triggerlist "upsmon" triggerlist
|
|
|
|
. "${IPKG_INSTROOT}"/lib/functions/network.sh
|
|
|
|
if [ -n "$triggerlist" ]; then
|
|
for trigger in $triggerlist; do
|
|
if [ "$action" = "add_trigger" ]; then
|
|
procd_add_interface_trigger "interface.*" "$trigger" /etc/init.d/nut-monitor restart
|
|
else
|
|
network_is_up "$trigger" && return 0
|
|
fi
|
|
done
|
|
else
|
|
if [ "$action" = "add_trigger" ]; then
|
|
procd_add_raw_trigger "interface.*.up" 2000 /etc/init.d/nut-monitor restart
|
|
else
|
|
ubus call network.device status | grep -q '"up": true' && return 0
|
|
fi
|
|
fi
|
|
[ "$action" = "add_trigger" ] || return 1
|
|
}
|
|
|
|
start_service() {
|
|
local runas=nutmon
|
|
local havemon havems
|
|
build_config
|
|
|
|
[ "$havemon" != 1 ] && return 1
|
|
[ "$havems" != 1 ] && return 1
|
|
interface_triggers "check_interface_up" || return 0
|
|
|
|
procd_open_instance "upsmon"
|
|
procd_set_param respawn 10 20 6
|
|
procd_set_param stderr 1
|
|
procd_set_param stdout 0
|
|
procd_set_param command /usr/sbin/upsmon -D
|
|
procd_close_instance
|
|
|
|
return 0
|
|
}
|
|
|
|
reload_service() {
|
|
if pgrep upsmon >/dev/null 2>/dev/null; then
|
|
local runas=nutmon
|
|
build_config
|
|
/usr/sbin/upsmon -c reload
|
|
else
|
|
restart
|
|
fi
|
|
}
|
|
|
|
stop_service() {
|
|
upsmon -c stop
|
|
}
|
|
|
|
service_triggers() {
|
|
config_load nut_monitor
|
|
interface_triggers "add_trigger"
|
|
procd_add_reload_trigger "nut_monitor"
|
|
}
|