From: Jo-Philipp Wich <jo@mein.io>
|
|
Date: Thu, 26 Jan 2017 15:30:00 +0100
|
|
Subject: [PATCH] config: adjust default values
|
|
|
|
Adjust the default interval settings to be better suited for slower embedded
|
|
devices.
|
|
|
|
Signed-off-by: Jo-Philipp Wich <jo@mein.io>
|
|
|
|
--- a/cfg/vnstat.conf
|
|
+++ b/cfg/vnstat.conf
|
|
@@ -87,13 +87,13 @@ DaemonUser ""
|
|
DaemonGroup ""
|
|
|
|
# how often (in seconds) interface data is updated
|
|
-UpdateInterval 30
|
|
+UpdateInterval 60
|
|
|
|
# how often (in seconds) interface status changes are checked
|
|
-PollInterval 5
|
|
+PollInterval 30
|
|
|
|
# how often (in minutes) data is saved to file
|
|
-SaveInterval 5
|
|
+SaveInterval 30
|
|
|
|
# how often (in minutes) data is saved when all interface are offline
|
|
OfflineSaveInterval 30
|