#!/bin/sh /etc/rc.common START=60 USE_PROCD=1 UPSMON_C=/var/etc/nut/upsmon.conf nut_upsmon_conf() { local cfg="$1" echo "# Config file automatically generated from UCI config" > $UPSMON_C config_get runas "$cfg" runas "nut" [ -n "$runas" ] && echo "RUN_AS_USER $runas" >> $UPSMON_C config_get val "$cfg" minsupplies 1 echo "MINSUPPLIES $val" >> $UPSMON_C config_get val "$cfg" shutdowncmd "/sbin/halt" echo "SHUTDOWNCMD \"$val\"" >> $UPSMON_C config_get val "$cfg" notifycmd [ -n "$val" ] && echo "NOTIFYCMD \"$val\"" >> $UPSMON_C config_get val "$cfg" pollfreq 5 echo "POLLFREQ $val" >> $UPSMON_C config_get val "$cfg" pollfreqalert 5 echo "POLLFREQALERT $val" >> $UPSMON_C config_get val "$cfg" hostsync 15 echo "HOSTSYNC $val" >> $UPSMON_C config_get val "$cfg" deadtime 15 echo "DEADTIME $val" >> $UPSMON_C config_get val "$cfg" powerdownflag /var/run/killpower echo "POWERDOWNFLAG $val" >> $UPSMON_C config_get val "$cfg" onlinemsg [ -n "$val" ] && echo "NOTIFYMSG ONLINE \"$val\"" >> $UPSMON_C config_get val "$cfg" onbattmsg [ -n "$val" ] && echo "NOTIFYMSG ONBATT \"$val\"" >> $UPSMON_C config_get val "$cfg" lowbattmsg [ -n "$val" ] && echo "NOTIFYMSG LOWBATT \"$val\"" >> $UPSMON_C config_get val "$cfg" fsdmsg [ -n "$val" ] && echo "NOTIFYMSG FSD \"$val\"" >> $UPSMON_C config_get val "$cfg" commokmsg [ -n "$val" ] && echo "NOTIFYMSG COMMOK \"$val\"" >> $UPSMON_C config_get val "$cfg" commbadmsg [ -n "$val" ] && echo "NOTIFYMSG COMMBAD \"$val\"" >> $UPSMON_C config_get val "$cfg" shutdownmsg [ -n "$val" ] && echo "NOTIFYMSG SHUTDOWN \"$val\"" >> $UPSMON_C config_get val "$cfg" replbattmsg [ -n "$val" ] && echo "NOTIFYMSG REPLBATT \"$val\"" >> $UPSMON_C config_get val "$cfg" nocommmsg [ -n "$val" ] && echo "NOTIFYMSG NOCOMM \"$val\"" >> $UPSMON_C config_get val "$cfg" noparentmsg [ -n "$val" ] && echo "NOTIFYMSG NOPARENT \"$val\"" >> $UPSMON_C notifylist() { local value="$1" append optval "$value" "+" } setnotify() { local cfg="$1" local optname="$2" local optval config_list_foreach "$cfg" "$optname" notifylist if [ -z "$optval" ]; then # If no list fallback to trying option, fallback to default config_get optval "$cfg" "$optname" "$default" if [ -n "$optval" ]; then echo "$optval" else # No default, so do the NUT default echo "SYSLOG" fi else echo "$optval" fi } local default optval val="" config_list_foreach "$cfg" defaultnotify notifylist default="$optval" echo "NOTIFYFLAG ONLINE $(setnotify "$cfg" onlinenotify)" >> $UPSMON_C echo "NOTIFYFLAG ONBATT $(setnotify "$cfg" onbattnotify)" >> $UPSMON_C echo "NOTIFYFLAG LOWBATT $(setnotify "$cfg" lowbatnotify)" >> $UPSMON_C echo "NOTIFYFLAG FSD $(setnotify "$cfg" fsdnotify)" >> $UPSMON_C echo "NOTIFYFLAG COMMOK $(setnotify "$cfg" commoknotify)" >> $UPSMON_C echo "NOTIFYFLAG COMMBAD $(setnotify "$cfg" commbadnotify)" >> $UPSMON_C echo "NOTIFYFLAG SHUTDOWN $(setnotify "$cfg" shutdownnotify)" >> $UPSMON_C echo "NOTIFYFLAG REPLBATT $(setnotify "$cfg" repolbattnotify)" >> $UPSMON_C echo "NOTIFYFLAG NOCOMM $(setnotify "$cfg" nocommnotify)" >> $UPSMON_C echo "NOTIFYFLAG NOPARENT $(setnotify "$cfg" noparentnotify)" >> $UPSMON_C config_get val "$cfg" rbwarntime 43200 echo "RBWARNTIME $val" >> $UPSMON_C config_get val "$cfg" nocommwarntime 300 echo "NOCOMMWARNTIME $val" >> $UPSMON_C config_get val "$cfg" finaldelay 5 echo "FINALDELAY $val" >> $UPSMON_C config_get val "$cfg" certpath if [ -n "$val" ]; then echo "CERTPATH $val" >> $UPSMON_C; fi config_get_bool val "$cfg" certverify 0 if [ -n "$val" ]; then echo "CERTVERIFY $val" >> $UPSMON_C; fi config_get_bool val "$cfg" forcessl 0 if [ -n "$val" ]; then echo "FORCESSL $val" >> $UPSMON_C; fi } nut_upsmon_add() { local cfg="$1" local type="$2" local upsname local hostname local port local powervalue local username local password local system # If no core config, use defaults [ -r $UPSMON_C ] || nut_upsmon_conf "" config_get upsname "$cfg" upsname config_get hostname "$cfg" hostname localhost config_get port "$cfg" port config_get powervalue "$cfg" powervalue 1 config_get username "$cfg" username config_get password "$cfg" password system="$upsname@$hostname" if [ -n "$port" ]; then system="$system:$port"; fi echo "MONITOR $system $powervalue $username $password $type" >> $UPSMON_C } start_service() { rm -f $UPSMON_C config_load nut_monitor config_foreach nut_upsmon_conf upsmon config_foreach nut_upsmon_add master master config_foreach nut_upsmon_add slave slave [ -z "$(cat /var/etc/nut/nut.conf)" ] && echo "MODE=netclient" >>/var/etc/nut/nut.conf chmod 640 $UPSMON_C chmod 640 /var/etc/nut/nut.conf [ -d /var/run/nut ] || { mkdir -m 0750 -p /var/run/nut chown ${runas:-root}:$(id -gn ${runas:-root}) /var/run/nut } chown ${runas:-root}:$(id -gn ${runas:-root}) $UPSMON_C $DEBUG /usr/sbin/upsmon $UPSMON_OPTIONS } stop_service() { [ -r $PID_F ] && /usr/sbin/upsmon -c stop rm -f $UPSMON_C } reload_service() { upsmon -c reload }