Remove "prompt" command, dropped in kconfig-v5.6, from
Package/sane-backends/config, replacing it with "tristate". This does
not affect the generated package.
Signed-off-by: Eneas U de Queiroz <cotequeiroz@gmail.com>
- Migrate libusb dependency back to libsane
(virtually all useful backends for OpenWrt would need it anyway)
- Disabled new usb-record-replay feature (avoid libxml2 dep)
- Disabled new escl backend (network-only backend are not too useful
for OpenWrt and it requires libcurl, libnetsnmp, libavahi and libxml2)
- Workaround sane-daemon/postinst installation on Imagebuild
- Enabled backends kvs40xx and mustek_usb2 (fixed upstream)
- Fix bigendian compilation
(https://gitlab.com/sane-project/backends/-/merge_requests/329)
- Fix missing std::round() for uclibc
(https://gitlab.com/sane-project/backends/issues/237)
- Fixes FS#2685: coldplug was running before usblp was loaded. Now
it grants access do usblp when a device using it is plugged.
Signed-off-by: Luiz Angelo Daros de Luca <luizluca@gmail.com>
saned requires write access scanner USB bus for its process and
to usblp/bind in order to rebind multifunctional printers back
to usblp (for printing with p910nd).
A hotplug script monitor new USB devices for scanners. Scanners
are detected by searching /usr/share/sane/<vendor>-<backend>.usbid
for the device product_id.
The package saned creates user saned:scanners. Access is granted to
group scanners.
The default xinetd conf was updated to run as saned:scanner.
sane-daemon pkg now has a postinst trigger that runs udevtrigger for
granting perms where there are connected scanners during installation.
Existing hotplug scripts from hplip were removed. They were mostly
useless.
Signed-off-by: Luiz Angelo Daros de Luca <luizluca@gmail.com>
Just Need runtime tests
* libsane dependency on libusb moved to those drivers that requires it
* clean up some ./configure args
* added saned-ricoh2 for new backend
* enabled saned-gphoto2 (after c8fbe26c53)
* disabled kvs40xx and mustek_usb2 that requires pthread while the issue is
not solved (https://gitlab.com/sane-project/backends/issues/153)
* patches refreshed:
- 002-remove-uneeded.patch
* patches dropped:
- 031-fix_uclibc.patch
- 050-remove_linked_libs_for_unused_preload.patch (with --disable-preload)
Signed-off-by: Luiz Angelo Daros de Luca <luizluca@gmail.com>
The CONTRIBUTING.md requests an (or multiple) SPDX identifier for GPL
licenses. But a lot of packages did use a different, non-SPDX style with a
"+" at the end instead of "-or-later".
Signed-off-by: Sven Eckelmann <sven@narfation.org>
While scanning, sane unbinds usb device from usblp module. This
patch creates a saned wrapper that keep track of all usb devices
binded to usblp before saned is launched and rebind them back
if not still bound after saned exits.
This workaround is only effective if saned is launched by a super
daemon like xinetd as it needs to exit after scan job finish. If
not, printing will not be available while saned service is running.
Write access to /sys/bus/usb/drivers/usblp/bind is required. So,
normally it would require root access.
Signed-off-by: Luiz Angelo Daros de Luca <luizluca@gmail.com>
libusb-compat was still required by package but sane was already
builing and linking libusb-1.0. It was working because libusb-compat
requires libusb-1.0.
Signed-off-by: Luiz Angelo Daros de Luca <luizluca@gmail.com>
Fixes CVE-2017-6318
Patches where refreshed and the following removed:
- 020-fix_pieusb.patch: fixed upstream
- 030-musl.patch: accepted upstream
PS: there was no sane-backends 1.0.26
Signed-off-by: Luiz Angelo Daros de Luca <luizluca@gmail.com>
sane-xxx backend packages are hidden packages with custom
config and CONFIG_ALL does not select them alone. Now
sane-backends depends on +ALL:sane-backends-all.
No existing ipk is affected as the changed package/sane-backends
does not exist as an ipk.
030-musl.patch was updated to be submitted upstream. However,
the added preprocessor #if are always true for OpenWRT and will
not change the resulting code.
Signed-off-by: Luiz Angelo Daros de Luca <luizluca@gmail.com>
Changes since oldpackages:
- updated to 1.0.25
* most of openwrt patches are upstreamed now
- cups dependency was completely removed
- small musl patch
- small uclibc patch
- removed link to extra libraries in libsane (used only
for preload backends)
- sane-libs and sane-backends merged and exploded into
individual packages for each backend:
* libsane for sane library (which backends should dep on)
* sane-daemon for saned daemon
* sane-xxx for sane backend for xxx
** each backend has its own custom dep libraries
* sane-backends-all (with no files) that deps on all backends
* sane-qcam is only available for x86/x86_64
** other archs does not implement inb/outb (at least in musl)
Now it is possible to use SANE with much less FS space (KB
instead of MB).
Signed-off-by: Luiz Angelo Daros de Luca <luizluca@gmail.com>
Changes since oldpackages:
- cups dependency was completely removed
* This also happened in sane trunk version
- small musl patch
- added detection of inb,outb (link error with musl)
* this also removes hack 020-non-i386-qcam.patch
- fix for segfault when using sane-test backend
- removed link to extra libraries in libsane (used only
for preload backends)
- added format-security fix
- sane-libs and sane-backends merged and exploded into
individual packages for each backend:
* libsane for sane library (which backends should dep on)
* sane-daemon for saned daemon
* sane-xxx for sane backend for xxx
** each backend has its own custom dep libraries
* sane-backends-all (with no files) that deps on all backends
* sane-qcam is only available for x86/x86_64
** other archs does not implement inb/outb (at least in musl)
Now it is possible to use SANE with much less FS space (KB
instead of MB).
Signed-off-by: Luiz Angelo Daros de Luca <luizluca@gmail.com>