Merge pull request #919 from tru7/apcupsd

apcupsd: move from old packages and Makefile updated
lilik-openwrt-22.03
Ted Hess 10 years ago
parent
commit
a3bacc1389
11 changed files with 663 additions and 0 deletions
  1. +78
    -0
      net/apcupsd/Makefile
  2. +146
    -0
      net/apcupsd/files/apccontrol
  3. +322
    -0
      net/apcupsd/files/apcupsd.conf
  4. +12
    -0
      net/apcupsd/files/apcupsd.init
  5. +7
    -0
      net/apcupsd/files/apcupsd_mail.conf
  6. +17
    -0
      net/apcupsd/files/changeme
  7. +17
    -0
      net/apcupsd/files/commfailure
  8. +17
    -0
      net/apcupsd/files/commok
  9. +17
    -0
      net/apcupsd/files/offbattery
  10. +17
    -0
      net/apcupsd/files/onbattery
  11. +13
    -0
      net/apcupsd/patches/010-fix-include-paths.patch

+ 78
- 0
net/apcupsd/Makefile View File

@ -0,0 +1,78 @@
#
# Copyright (C) 2006-2015 OpenWrt.org
#
# This is free software, licensed under the GNU General Public License v2.
# See /LICENSE for more information.
#
include $(TOPDIR)/rules.mk
PKG_NAME:=apcupsd
PKG_VERSION:=3.14.13
PKG_RELEASE:=2
PKG_MAINTAINER:=Othmar Truniger <github@truniger.ch>
PKG_LICENSE:=GPL-2.0
PKG_LICENSE_FILES:=COPYING
PKG_SOURCE:=$(PKG_NAME)-$(PKG_VERSION).tar.gz
PKG_SOURCE_URL:=@SF/apcupsd
PKG_MD5SUM:=c291d9d3923b4d9c0e600b755ad4f489
include $(INCLUDE_DIR)/package.mk
define Package/apcupsd
SECTION:=utils
CATEGORY:=Utilities
DEPENDS:=+libpthread +libusb-compat
TITLE:=UPS control software
URL:=http://www.apcupsd.org/
endef
define Build/Configure
$(CP) $(SCRIPT_DIR)/config.* $(PKG_BUILD_DIR)/autoconf/
$(call Build/Configure/Default, \
--with-distname=unknown \
--sysconfdir=/etc/apcupsd \
--enable-usb \
--without-x \
)
endef
define Build/Compile
$(MAKE) -C $(PKG_BUILD_DIR) \
DESTDIR="$(PKG_INSTALL_DIR)" \
LD="$(TARGET_CC)" \
all install
endef
define Package/apcupsd/install
$(INSTALL_DIR) $(1)/usr/sbin
$(INSTALL_BIN) $(PKG_INSTALL_DIR)/usr/sbin/apcupsd $(1)/usr/sbin/
$(INSTALL_BIN) $(PKG_INSTALL_DIR)/usr/sbin/smtp $(1)/usr/sbin/
$(INSTALL_BIN) $(PKG_INSTALL_DIR)/usr/sbin/apctest $(1)/usr/sbin/
$(INSTALL_BIN) $(PKG_INSTALL_DIR)/usr/sbin/apcaccess $(1)/usr/sbin/
$(INSTALL_DIR) $(1)/etc/apcupsd
$(INSTALL_CONF) ./files/apcupsd.conf $(1)/etc/apcupsd/
$(INSTALL_CONF) ./files/apcupsd_mail.conf $(1)/etc/apcupsd/
$(INSTALL_BIN) ./files/changeme $(1)/etc/apcupsd/
$(INSTALL_BIN) ./files/commfailure $(1)/etc/apcupsd/
$(INSTALL_BIN) ./files/commok $(1)/etc/apcupsd/
$(INSTALL_BIN) ./files/offbattery $(1)/etc/apcupsd/
$(INSTALL_BIN) ./files/onbattery $(1)/etc/apcupsd/
$(INSTALL_BIN) ./files/apccontrol $(1)/etc/apcupsd/
$(INSTALL_DIR) $(1)/etc/init.d
$(INSTALL_BIN) ./files/apcupsd.init $(1)/etc/init.d/apcupsd
endef
define Package/apcupsd/conffiles
/etc/apcupsd/apcupsd.conf
/etc/apcupsd/apcupsd_mail.conf
/etc/apcupsd/changeme
/etc/apcupsd/commfailure
/etc/apcupsd/commok
/etc/apcupsd/offbattery
/etc/apcupsd/onbattery
endef
$(eval $(call BuildPackage,apcupsd))

+ 146
- 0
net/apcupsd/files/apccontrol View File

@ -0,0 +1,146 @@
#!/bin/sh
#
# Copyright (C) 1999-2002 Riccardo Facchetti <riccardo@master.oasi.gpa.it>
#
# for apcupsd release 3.14.1 (04 May 2007) - unknown
#
# platforms/apccontrol. Generated from apccontrol.in by configure.
#
# Note, this is a generic file that can be used by most
# systems. If a particular system needs to have something
# special, start with this file, and put a copy in the
# platform subdirectory.
#
#
# These variables are needed for set up the autoconf other variables.
#
prefix=/usr
exec_prefix=/usr
APCPID=/var/run/apcupsd.pid
APCUPSD=/usr/sbin/apcupsd
SHUTDOWN=/sbin/shutdown
SCRIPTSHELL=/bin/sh
SCRIPTDIR=/etc/apcupsd
WALL=true
#
# Concatenate all output from this script to the events file
# Note, the following kills the script in a power fail situation
# where the disks are mounted read-only.
# exec >>/var/log/apcupsd.events 2>&1
#
# This piece is to substitute the default behaviour with your own script,
# perl, or C program.
# You can customize every single command creating an executable file (may be a
# script or a compiled program) and calling it the same as the $1 parameter
# passed by apcupsd to this script.
#
# After executing your script, apccontrol continues with the default action.
# If you do not want apccontrol to continue, exit your script with exit
# code 99. E.g. "exit 99".
#
# WARNING: the apccontrol file will be overwritten every time you update your
# apcupsd, doing `make install'. Your own customized scripts will _not_ be
# overwritten. If you wish to make changes to this file (discouraged), you
# should change apccontrol.sh.in and then rerun the configure process.
#
if [ -f ${SCRIPTDIR}/${1} -a -x ${SCRIPTDIR}/${1} ]
then
${SCRIPTDIR}/${1} ${2} ${3} ${4}
# exit code 99 means he does not want us to do default action
if [ $? = 99 ] ; then
exit 0
fi
fi
case "$1" in
killpower)
echo "Apccontrol doing: ${APCUPSD} --killpower on UPS ${2}"
sleep 10
${APCUPSD} --killpower
echo "Apccontrol has done: ${APCUPSD} --killpower on UPS ${2}" | ${WALL}
;;
commfailure)
echo "Warning communications lost with UPS ${2}" | ${WALL}
;;
commok)
echo "Communications restored with UPS ${2}" | ${WALL}
;;
#
# powerout, onbattery, offbattery, mainsback events occur
# in that order.
#
powerout)
echo "Warning power loss detected on UPS ${2}" | ${WALL}
;;
onbattery)
echo "Power failure on UPS ${2}. Running on batteries." | ${WALL}
;;
offbattery)
;;
mainsback)
echo "Power has returned on UPS ${2}..." | ${WALL}
if [ -f /etc/powerfail ] ; then
printf "Continuing with shutdown." | ${WALL}
fi
;;
failing)
echo "Battery power exhaused on UPS ${2}. Doing shutdown." | ${WALL}
;;
timeout)
echo "Battery time limit exceeded on UPS ${2}. Doing shutdown." | ${WALL}
;;
loadlimit)
echo "Remaining battery charge below limit on UPS ${2}. Doing shutdown." | ${WALL}
;;
runlimit)
echo "Remaining battery runtime below limit on UPS ${2}. Doing shutdown." | ${WALL}
;;
doreboot)
echo "UPS ${2} initiating Reboot Sequence" | ${WALL}
${SHUTDOWN} -r now "apcupsd UPS ${2} initiated reboot"
;;
doshutdown)
echo "UPS ${2} initiated Shutdown Sequence" | ${WALL}
${SHUTDOWN} -h now "apcupsd UPS ${2} initiated shutdown"
;;
annoyme)
echo "Power problems with UPS ${2}. Please logoff." | ${WALL}
;;
emergency)
echo "Emergency Shutdown. Possible battery failure on UPS ${2}." | ${WALL}
;;
changeme)
echo "Emergency! Batteries have failed on UPS ${2}. Change them NOW" | ${WALL}
;;
remotedown)
echo "Remote Shutdown. Beginning Shutdown Sequence." | ${WALL}
;;
restartme)
echo -n "Restarting APCUPSD Power Management: "
THEPID=`cat ${APCPID}`
kill ${THEPID}
rm -f ${APCPID}
rm -f /etc/powerfail
rm -f /etc/nologin
sleep 5
`${APCUPSD}`
echo "apcupsd"
;;
startselftest)
;;
endselftest)
;;
battdetach)
;;
battattach)
;;
*) echo "Usage: ${0##*/} command"
echo " warning: this script is intended to be launched by"
echo " apcupsd and should never be launched by users."
exit 1
;;
esac

+ 322
- 0
net/apcupsd/files/apcupsd.conf View File

@ -0,0 +1,322 @@
## apcupsd.conf v1.1 ##
#
# for apcupsd release 3.14.1 (04 May 2007) - unknown
#
# "apcupsd" POSIX config file
#
# ========= General configuration parameters ============
#
# UPSNAME xxx
# Use this to give your UPS a name in log files and such. This
# is particulary useful if you have multiple UPSes. This does not
# set the EEPROM. It should be 8 characters or less.
UPSNAME ups1
# UPSCABLE <cable>
# Defines the type of cable connecting the UPS to your computer.
#
# Possible generic choices for <cable> are:
# simple, smart, ether, usb
#
# Or a specific cable model number may be used:
# 940-0119A, 940-0127A, 940-0128A, 940-0020B,
# 940-0020C, 940-0023A, 940-0024B, 940-0024C,
# 940-1524C, 940-0024G, 940-0095A, 940-0095B,
# 940-0095C, M-04-02-2000
#
UPSCABLE smart
# To get apcupsd to work, in addition to defining the cable
# above, you must also define a UPSTYPE, which corresponds to
# the type of UPS you have (see the Description for more details).
# You must also specify a DEVICE, sometimes referred to as a port.
# For USB UPSes, please leave the DEVICE directive blank. For
# other UPS types, you must specify an appropriate port or address.
#
# UPSTYPE DEVICE Description
# apcsmart /dev/tty** Newer serial character device,
# appropriate for SmartUPS models using
# a serial cable (not USB).
#
# usb <BLANK> Most new UPSes are USB. A blank DEVICE
# setting enables autodetection, which is
# the best choice for most installations.
#
# net hostname:port Network link to a master apcupsd
# through apcupsd's Network Information
# Server. This is used if you don't have
# a UPS directly connected to your computer.
#
# snmp hostname:port:vendor:community
# SNMP Network link to an SNMP-enabled
# UPS device. Vendor is the MIB used by
# the UPS device: can be "APC", "APC_NOTRAP"
# or "RFC" where APC is the powernet MIB,
# "APC_NOTRAP" is powernet with SNMP trap
# catching disabled, and RFC is the IETF's
# rfc1628 UPS-MIB. You usually want "APC".
# Port is usually 161. Community is usually
# "private".
#
# dumb /dev/tty** Old serial character device for use
# with simple-signaling UPSes.
#
# pcnet ipaddr:username:passphrase
# PowerChute Network Shutdown protocol
# which can be used as an alternative to SNMP
# with AP9617 family of smart slot cards.
# ipaddr is the IP address of the UPS mgmt
# card. username and passphrase are the
# credentials for which the card has been
# configured.
#
UPSTYPE apcsmart
DEVICE /dev/ttyS0
# LOCKFILE <path to lockfile>
# Path for device lock file. Not used on Win32.
LOCKFILE /var/lock
# SCRIPTDIR <path to script directory>
# Directory in which apccontrol and event scripts are located.
SCRIPTDIR /etc/apcupsd
# PWRFAILDIR <path to powerfail directory>
# Directory in which to write the powerfail flag file. This file
# is created when apcupsd initiates a system shutdown and is
# checked in the OS halt scripts to determine if a killpower
# (turning off UPS output power) is required.
PWRFAILDIR /etc
# NOLOGINDIR <path to nologin directory>
# Directory in which to write the nologin file. The existence
# of this flag file tells the OS to disallow new logins.
NOLOGINDIR /etc
#
# ======== Configuration parameters used during power failures ==========
#
# The ONBATTERYDELAY is the time in seconds from when a power failure
# is detected until we react to it with an onbattery event.
#
# This means that, apccontrol will be called with the powerout argument
# immediately when a power failure is detected. However, the
# onbattery argument is passed to apccontrol only after the
# ONBATTERYDELAY time. If you don't want to be annoyed by short
# powerfailures, make sure that apccontrol powerout does nothing
# i.e. comment out the wall.
#ONBATTERYDELAY 6
#
# Note: BATTERYLEVEL, MINUTES, and TIMEOUT work in conjunction, so
# the first that occurs will cause the initation of a shutdown.
#
# If during a power failure, the remaining battery percentage
# (as reported by the UPS) is below or equal to BATTERYLEVEL,
# apcupsd will initiate a system shutdown.
BATTERYLEVEL 5
# If during a power failure, the remaining runtime in minutes
# (as calculated internally by the UPS) is below or equal to MINUTES,
# apcupsd, will initiate a system shutdown.
MINUTES 3
# If during a power failure, the UPS has run on batteries for TIMEOUT
# many seconds or longer, apcupsd will initiate a system shutdown.
# A value of 0 disables this timer.
#
# Note, if you have a Smart UPS, you will most likely want to disable
# this timer by setting it to zero. That way, you UPS will continue
# on batteries until either the % charge remaing drops to or below BATTERYLEVEL,
# or the remaining battery runtime drops to or below MINUTES. Of course,
# if you are testing, setting this to 60 causes a quick system shutdown
# if you pull the power plug.
# If you have an older dumb UPS, you will want to set this to less than
# the time you know you can run on batteries.
TIMEOUT 0
# Time in seconds between annoying users to signoff prior to
# system shutdown. 0 disables.
ANNOY 300
# Initial delay after power failure before warning users to get
# off the system.
ANNOYDELAY 60
# The condition which determines when users are prevented from
# logging in during a power failure.
# NOLOGON <string> [ disable | timeout | percent | minutes | always ]
NOLOGON disable
# If KILLDELAY is non-zero, apcupsd will continue running after a
# shutdown has been requested, and after the specified time in
# seconds attempt to kill the power. This is for use on systems
# where apcupsd cannot regain control after a shutdown.
# KILLDELAY <seconds> 0 disables
KILLDELAY 0
#
# ==== Configuration statements for Network Information Server ====
#
# NETSERVER [ on | off ] on enables, off disables the network
# information server. If netstatus is on, a network information
# server process will be started for serving the STATUS and
# EVENT data over the network (used by CGI programs).
NETSERVER on
# NISIP <dotted notation ip address>
# IP address on which NIS server will listen for incoming connections.
# This is useful if your server is multi-homed (has more than one
# network interface and IP address). Default value is 0.0.0.0 which
# means any incoming request will be serviced. Alternatively, you can
# configure this setting to any specific IP address of your server and
# NIS will listen for connections only on that interface. Use the
# loopback address (127.0.0.1) to accept connections only from the
# local machine.
NISIP 0.0.0.0
# NISPORT <port> default is 3551 as registered with the IANA
# port to use for sending STATUS and EVENTS data over the network.
# It is not used unless NETSERVER is on. If you change this port,
# you will need to change the corresponding value in the cgi directory
# and rebuild the cgi programs.
NISPORT 3551
# If you want the last few EVENTS to be available over the network
# by the network information server, you must define an EVENTSFILE.
EVENTSFILE /var/log/apcupsd.events
# EVENTSFILEMAX <kilobytes>
# By default, the size of the EVENTSFILE will be not be allowed to exceed
# 10 kilobytes. When the file grows beyond this limit, older EVENTS will
# be removed from the beginning of the file (first in first out). The
# parameter EVENTSFILEMAX can be set to a different kilobyte value, or set
# to zero to allow the EVENTSFILE to grow without limit.
EVENTSFILEMAX 10
#
# ========== Configuration statements used if sharing =============
# a UPS with more than one machine
# NETTIME <int>
# Interval (in seconds) at which the NIS client polls the server.
# Used only when this apcupsd is a network client (UPSTYPE net).
#NETTIME 60
#
# Remaining items are for ShareUPS (APC expansion card) ONLY
#
# UPSCLASS [ standalone | shareslave | sharemaster ]
# Normally standalone unless you share an UPS using an APC ShareUPS
# card.
UPSCLASS standalone
# UPSMODE [ disable | share ]
# Normally disable unless you share an UPS using an APC ShareUPS card.
UPSMODE disable
#
# ===== Configuration statements to control apcupsd system logging ========
#
# Time interval in seconds between writing the STATUS file; 0 disables
STATTIME 0
# Location of STATUS file (written to only if STATTIME is non-zero)
STATFILE /var/log/apcupsd.status
# LOGSTATS [ on | off ] on enables, off disables
# Note! This generates a lot of output, so if
# you turn this on, be sure that the
# file defined in syslog.conf for LOG_NOTICE is a named pipe.
# You probably do not want this on.
LOGSTATS off
# Time interval in seconds between writing the DATA records to
# the log file. 0 disables.
DATATIME 0
# FACILITY defines the logging facility (class) for logging to syslog.
# If not specified, it defaults to "daemon". This is useful
# if you want to separate the data logged by apcupsd from other
# programs.
#FACILITY DAEMON
#
# ========== Configuration statements used in updating the UPS EPROM =========
#
#
# These statements are used only by apctest when choosing "Set EEPROM with conf
# file values" from the EEPROM menu. THESE STATEMENTS HAVE NO EFFECT ON APCUPSD.
#
# UPS name, max 8 characters
#UPSNAME UPS_IDEN
# Battery date - 8 characters
#BATTDATE mm/dd/yy
# Sensitivity to line voltage quality (H cause faster transfer to batteries)
# SENSITIVITY H M L (default = H)
#SENSITIVITY H
# UPS delay after power return (seconds)
# WAKEUP 000 060 180 300 (default = 0)
#WAKEUP 60
# UPS Grace period after request to power off (seconds)
# SLEEP 020 180 300 600 (default = 20)
#SLEEP 180
# Low line voltage causing transfer to batteries
# The permitted values depend on your model as defined by last letter
# of FIRMWARE or APCMODEL. Some representative values are:
# D 106 103 100 097
# M 177 172 168 182
# A 092 090 088 086
# I 208 204 200 196 (default = 0 => not valid)
#LOTRANSFER 208
# High line voltage causing transfer to batteries
# The permitted values depend on your model as defined by last letter
# of FIRMWARE or APCMODEL. Some representative values are:
# D 127 130 133 136
# M 229 234 239 224
# A 108 110 112 114
# I 253 257 261 265 (default = 0 => not valid)
#HITRANSFER 253
# Battery charge needed to restore power
# RETURNCHARGE 00 15 50 90 (default = 15)
#RETURNCHARGE 15
# Alarm delay
# 0 = zero delay after pwr fail, T = power fail + 30 sec, L = low battery, N = never
# BEEPSTATE 0 T L N (default = 0)
#BEEPSTATE T
# Low battery warning delay in minutes
# LOWBATT 02 05 07 10 (default = 02)
#LOWBATT 2
# UPS Output voltage when running on batteries
# The permitted values depend on your model as defined by last letter
# of FIRMWARE or APCMODEL. Some representative values are:
# D 115
# M 208
# A 100
# I 230 240 220 225 (default = 0 => not valid)
#OUTPUTVOLTS 230
# Self test interval in hours 336=2 weeks, 168=1 week, ON=at power on
# SELFTEST 336 168 ON OFF (default = 336)
#SELFTEST 336

+ 12
- 0
net/apcupsd/files/apcupsd.init View File

@ -0,0 +1,12 @@
#!/bin/sh /etc/rc.common
# Copyright (C) 2006 OpenWrt.org
START=50
STOP=50
start() {
/usr/sbin/apcupsd -f /etc/apcupsd/apcupsd.conf
}
stop() {
kill $(cat /var/run/apcupsd.pid)
}

+ 7
- 0
net/apcupsd/files/apcupsd_mail.conf View File

@ -0,0 +1,7 @@
#!/bin/sh
MAILPROG="/usr/sbin/smtp"
MAILHOST="mail:25"
FROM="OpenWrt"
TO="apcups@example.com"
HOSTNAME="OpenWrt"

+ 17
- 0
net/apcupsd/files/changeme View File

@ -0,0 +1,17 @@
#!/bin/sh
#
# This shell script if placed in /etc/apcupsd
# will be called by /etc/apcupsd/apccontrol when apcupsd
# detects that the battery should be replaced.
# We send an email message to root to notify him.
#
. /etc/apcupsd/apcupsd_mail.conf
MSG="$HOSTNAME UPS battery needs changing NOW."
#
(
echo "$MSG"
echo " "
/usr/sbin/apcaccess status
) | $MAILPROG -h $MAILHOST -f $FROM -s "$MSG" $TO
exit 0

+ 17
- 0
net/apcupsd/files/commfailure View File

@ -0,0 +1,17 @@
#!/bin/sh
#
# This shell script if placed in /etc/apcupsd
# will be called by /etc/apcupsd/apccontrol when apcupsd
# loses contact with the UPS (i.e. the serial connection is not responding).
# We send an email message to root to notify him.
#
. /etc/apcupsd/apcupsd_mail.conf
MSG="$HOSTNAME Communications with UPS lost"
#
(
echo "$MSG"
echo " "
/usr/sbin/apcaccess status
) | $MAILPROG -h $MAILHOST -f $FROM -s "$MSG" $TO
exit 0

+ 17
- 0
net/apcupsd/files/commok View File

@ -0,0 +1,17 @@
#!/bin/sh
#
# This shell script if placed in /etc/apcupsd
# will be called by /etc/apcupsd/apccontrol when apcupsd
# restores contact with the UPS (i.e. the serial connection is restored).
# We send an email message to root to notify him.
#
. /etc/apcupsd/apcupsd_mail.conf
MSG="$HOSTNAME Communications with UPS restored"
#
(
echo "$MSG"
echo " "
/usr/sbin/apcaccess status
) | $MAILPROG -h $MAILHOST -f $FROM -s "$MSG" $TO
exit 0

+ 17
- 0
net/apcupsd/files/offbattery View File

@ -0,0 +1,17 @@
#!/bin/sh
#
# This shell script if placed in /etc/apcupsd
# will be called by /etc/apcupsd/apccontrol when apcupsd
# restores contact with the UPS (i.e. the serial connection is restored).
# We send an email message to root to notify him.
#
. /etc/apcupsd/apcupsd_mail.conf
MSG="$HOSTNAME Communications with UPS restored"
#
(
echo "$MSG"
echo " "
/usr/sbin/apcaccess status
) | $MAILPROG -h $MAILHOST -f $FROM -s "$MSG" $TO
exit 0

+ 17
- 0
net/apcupsd/files/onbattery View File

@ -0,0 +1,17 @@
#!/bin/sh
#
# This shell script if placed in /etc/apcupsd
# will be called by /etc/apcupsd/apccontrol when the UPS
# goes on batteries.
# We send an email message to root to notify him.
#
. /etc/apcupsd/apcupsd_mail.conf
MSG="$HOSTNAME Power Failure !!!"
#
(
echo "$MSG"
echo " "
/usr/sbin/apcaccess status
) | $MAILPROG -h $MAILHOST -f $FROM -s "$MSG" $TO
exit 0

+ 13
- 0
net/apcupsd/patches/010-fix-include-paths.patch View File

@ -0,0 +1,13 @@
diff --git a/autoconf/variables.mak.in b/autoconf/variables.mak.in
index b67e467..6022434 100644
--- a/autoconf/variables.mak.in
+++ b/autoconf/variables.mak.in
@@ -65,7 +65,7 @@ DRVLIBS = @PTHREAD_LFLAGS@ @DRVLIBS@
X_LIBS = @X_LIBS@
X_EXTRA_LIBS = @X_EXTRA_LIBS@
-CPPFLAGS = @CPPFLAGS@ -I$(topdir)/include $(EXTRAINCS)
+CPPFLAGS = -I$(topdir)/include @CPPFLAGS@ $(EXTRAINCS)
CFLAGS = $(CPPFLAGS) @CFLAGS@ @PTHREAD_CFLAGS@
CXXFLAGS = $(CPPFLAGS) @CXXFLAGS@ @PTHREAD_CFLAGS@
LDFLAGS = @LDFLAGS@

Loading…
Cancel
Save