@ -0,0 +1,63 @@ |
|
|
|
# Sample multimon configuration file |
|
|
|
# |
|
|
|
# This file is not required. Without it, multimon will use the default |
|
|
|
# field layout. |
|
|
|
# |
|
|
|
# Temperature selection |
|
|
|
# |
|
|
|
# Pick "TEMPC" for Celsius or "TEMPF" for Fahrenheit. This will override |
|
|
|
# the --enable-celsius setting from the compile. UPSTEMP (below) will |
|
|
|
# use this setting by default. |
|
|
|
|
|
|
|
TEMPC |
|
|
|
|
|
|
|
# Format: |
|
|
|
# FIELD <variable> "<field name>" "<field suffix>" |
|
|
|
# |
|
|
|
# <variable> is either a word from the UPS protocol like battchg (see the |
|
|
|
# table in src/cgi/upsfetch.c) or a special word in uppercase. |
|
|
|
# |
|
|
|
# Special words are: |
|
|
|
# MODEL - Show the model name for this system in cyan |
|
|
|
# |
|
|
|
# STATUS - Parse the status for this system using the appropriate color |
|
|
|
# |
|
|
|
# UPSTEMP and AMBTEMP use the default scale. This is set to C if you use |
|
|
|
# --enable-celsius at compile time *or* if you use "TEMPC" above. |
|
|
|
# |
|
|
|
# UPSTEMP - Show the UPS temperature in the default scale (suffix ignored) |
|
|
|
# AMBTEMP - Show the ambient temperature in the default scale (suffix ignored) |
|
|
|
# |
|
|
|
# UPSTEMPC - Show the UPS temperature in degrees C (suffix ignored) |
|
|
|
# UPSTEMPF - Show the UPS temperature in degrees F (suffix ignored) |
|
|
|
# AMBTEMPC - Show the ambient temperature in degrees C (suffix ignored) |
|
|
|
# AMBTEMPF - Show the ambient temperature in degrees F (suffix ignored) |
|
|
|
# |
|
|
|
# They're called "special" since they actually understand the content |
|
|
|
# being printed and do other things based on what's in there. |
|
|
|
# |
|
|
|
# <field name> is what you'd like this column to be called on the page. |
|
|
|
# Remember that this is HTML, so you can actually embed markup in here. |
|
|
|
# This means you can even include images here. You can include quotes |
|
|
|
# (and backslashes!) in the string by escaping them with a backslash (\). |
|
|
|
# |
|
|
|
# <field suffix> is typically something like % or VAC. It's useful if |
|
|
|
# you want to convey the units that apply to a value. |
|
|
|
# |
|
|
|
# Example config |
|
|
|
|
|
|
|
FIELD SYSTEM "System" "" |
|
|
|
FIELD MODEL "Model" "" |
|
|
|
FIELD STATUS "Status" "" |
|
|
|
FIELD battpct "Battery Chg" "%" |
|
|
|
FIELD utility "Utility" "VAC" |
|
|
|
FIELD loadpct "UPS Load" "%" |
|
|
|
FIELD UPSTEMP "UPS Temp" "" |
|
|
|
FIELD runtime "Batt. Run Time" "min." |
|
|
|
FIELD DATA "Data" "All data" |
|
|
|
|
|
|
|
# These are only useful if you have a Smart-UPS model with the Measure-UPS II |
|
|
|
# measurement card. No other models presently support these features. |
|
|
|
# |
|
|
|
# FIELD AMBTEMP "Ambient Temp" "" |
|
|
|
# FIELD HUMIDITY "Ambient Humidity" "%" |