libmodbus: backport RS485 fixes

Import two patches from upstream in order to fix Modbus-RTU over RS485:
 1c5d969 Only set SER_RS485_ENABLED bit of existing RS485 settings
 91a1d74 Oops fix OR on RS485 settings (1c5d969)

Signed-off-by: Daniel Golle <daniel@makrotopia.org>
lilik-openwrt-22.03
Daniel Golle 6 years ago
parent
commit
3f808eb628
3 changed files with 69 additions and 1 deletions
  1. +1
    -1
      libs/libmodbus/Makefile
  2. +43
    -0
      libs/libmodbus/patches/0001-Only-set-SER_RS485_ENABLED-bit-of-existing-RS485-set.patch
  3. +25
    -0
      libs/libmodbus/patches/0002-Oops-fix-OR-on-RS485-settings-1c5d969.patch

+ 1
- 1
libs/libmodbus/Makefile View File

@ -9,7 +9,7 @@ include $(TOPDIR)/rules.mk
PKG_NAME:=libmodbus
PKG_VERSION:=3.1.4
PKG_RELEASE:=1
PKG_RELEASE:=2
PKG_SOURCE:=$(PKG_NAME)-$(PKG_VERSION).tar.gz
PKG_SOURCE_URL:=http://libmodbus.org/releases


+ 43
- 0
libs/libmodbus/patches/0001-Only-set-SER_RS485_ENABLED-bit-of-existing-RS485-set.patch View File

@ -0,0 +1,43 @@
From 1c5d969f46ccd5333f602dfbe2b0a1295650b9b0 Mon Sep 17 00:00:00 2001
From: =?UTF-8?q?St=C3=A9phane=20Raimbault?= <stephane.raimbault@gmail.com>
Date: Wed, 25 Oct 2017 20:35:47 +0200
Subject: [PATCH 1/2] Only set SER_RS485_ENABLED bit of existing RS485 settings
Thanks to @JCWren
---
src/modbus-rtu.c | 10 +++++++++-
1 file changed, 9 insertions(+), 1 deletion(-)
diff --git a/src/modbus-rtu.c b/src/modbus-rtu.c
index 8d9f386..f2911d6 100644
--- a/src/modbus-rtu.c
+++ b/src/modbus-rtu.c
@@ -909,9 +909,13 @@ int modbus_rtu_set_serial_mode(modbus_t *ctx, int mode)
#if HAVE_DECL_TIOCSRS485
modbus_rtu_t *ctx_rtu = ctx->backend_data;
struct serial_rs485 rs485conf;
- memset(&rs485conf, 0x0, sizeof(struct serial_rs485));
if (mode == MODBUS_RTU_RS485) {
+ // Get
+ if (ioctl(ctx->s, TIOCGRS485, &rs485conf) < 0) {
+ return -1;
+ }
+ // Set
rs485conf.flags = SER_RS485_ENABLED;
if (ioctl(ctx->s, TIOCSRS485, &rs485conf) < 0) {
return -1;
@@ -923,6 +927,10 @@ int modbus_rtu_set_serial_mode(modbus_t *ctx, int mode)
/* Turn off RS485 mode only if required */
if (ctx_rtu->serial_mode == MODBUS_RTU_RS485) {
/* The ioctl call is avoided because it can fail on some RS232 ports */
+ if (ioctl(ctx->s, TIOCGRS485, &rs485conf) < 0) {
+ return -1;
+ }
+ rs485conf.flags &= ~SER_RS485_ENABLED;
if (ioctl(ctx->s, TIOCSRS485, &rs485conf) < 0) {
return -1;
}
--
2.21.0

+ 25
- 0
libs/libmodbus/patches/0002-Oops-fix-OR-on-RS485-settings-1c5d969.patch View File

@ -0,0 +1,25 @@
From 91a1d74f76c64e7b35bfb10114e1a4a6ff351656 Mon Sep 17 00:00:00 2001
From: =?UTF-8?q?St=C3=A9phane=20Raimbault?= <stephane.raimbault@gmail.com>
Date: Thu, 26 Oct 2017 11:10:31 +0200
Subject: [PATCH 2/2] Oops fix OR on RS485 settings (1c5d969)
---
src/modbus-rtu.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/src/modbus-rtu.c b/src/modbus-rtu.c
index f2911d6..190298e 100644
--- a/src/modbus-rtu.c
+++ b/src/modbus-rtu.c
@@ -916,7 +916,7 @@ int modbus_rtu_set_serial_mode(modbus_t *ctx, int mode)
return -1;
}
// Set
- rs485conf.flags = SER_RS485_ENABLED;
+ rs485conf.flags |= SER_RS485_ENABLED;
if (ioctl(ctx->s, TIOCSRS485, &rs485conf) < 0) {
return -1;
}
--
2.21.0