  1. #!/bin/sh /etc/rc.common
  2. START=51
  3. USE_PROCD=1
  4. UPSMON_C=/var/etc/nut/upsmon.conf
  5. nut_upsmon_conf() {
  6. local cfg="$1"
  7. local RUNAS val optval
  8. echo "# Config file automatically generated from UCI config" > "$UPSMON_C"
  9. config_get RUNAS "$cfg" runas "nutmon"
  10. [ -n "$RUNAS" ] && echo "RUN_AS_USER $RUNAS" >> "$UPSMON_C"
  11. runas=$RUNAS
  12. config_get val "$cfg" minsupplies 1
  13. echo "MINSUPPLIES $val" >> "$UPSMON_C"
  14. config_get val "$cfg" shutdowncmd "/usr/sbin/nutshutdown"
  15. echo "SHUTDOWNCMD \"$val\"" >> "$UPSMON_C"
  16. config_get val "$cfg" notifycmd
  17. [ -n "$val" ] && echo "NOTIFYCMD \"$val\"" >> "$UPSMON_C"
  18. config_get val "$cfg" pollfreq 5
  19. echo "POLLFREQ $val" >> "$UPSMON_C"
  20. config_get val "$cfg" pollfreqalert 5
  21. echo "POLLFREQALERT $val" >> "$UPSMON_C"
  22. config_get val "$cfg" hostsync 15
  23. echo "HOSTSYNC $val" >> "$UPSMON_C"
  24. config_get val "$cfg" deadtime 15
  25. echo "DEADTIME $val" >> "$UPSMON_C"
  26. echo "POWERDOWNFLAG /var/run/killpower" >> "$UPSMON_C"
  27. config_get val "$cfg" onlinemsg
  28. [ -n "$val" ] && echo "NOTIFYMSG ONLINE \"$val\"" >> "$UPSMON_C"
  29. config_get val "$cfg" onbattmsg
  30. [ -n "$val" ] && echo "NOTIFYMSG ONBATT \"$val\"" >> "$UPSMON_C"
  31. config_get val "$cfg" lowbattmsg
  32. [ -n "$val" ] && echo "NOTIFYMSG LOWBATT \"$val\"" >> "$UPSMON_C"
  33. config_get val "$cfg" fsdmsg
  34. [ -n "$val" ] && echo "NOTIFYMSG FSD \"$val\"" >> "$UPSMON_C"
  35. config_get val "$cfg" commokmsg
  36. [ -n "$val" ] && echo "NOTIFYMSG COMMOK \"$val\"" >> "$UPSMON_C"
  37. config_get val "$cfg" commbadmsg
  38. [ -n "$val" ] && echo "NOTIFYMSG COMMBAD \"$val\"" >> "$UPSMON_C"
  39. config_get val "$cfg" shutdownmsg
  40. [ -n "$val" ] && echo "NOTIFYMSG SHUTDOWN \"$val\"" >> "$UPSMON_C"
  41. config_get val "$cfg" replbattmsg
  42. [ -n "$val" ] && echo "NOTIFYMSG REPLBATT \"$val\"" >> "$UPSMON_C"
  43. config_get val "$cfg" nocommmsg
  44. [ -n "$val" ] && echo "NOTIFYMSG NOCOMM \"$val\"" >> "$UPSMON_C"
  45. config_get val "$cfg" noparentmsg
  46. [ -n "$val" ] && echo "NOTIFYMSG NOPARENT \"$val\"" >> "$UPSMON_C"
  47. notifylist() {
  48. local value="$1"
  49. append optval "$value" "+"
  50. }
  51. setnotify() {
  52. local cfg="$1"
  53. local optname="$2"
  54. local optval
  55. config_list_foreach "$cfg" "$optname" notifylist
  56. if [ -z "$optval" ]; then
  57. # If no list fallback to trying option, fallback to default
  58. config_get optval "$cfg" "$optname" "$default"
  59. if [ -n "$optval" ]; then
  60. echo "$optval"
  61. else
  62. # No default, so do the NUT default
  63. echo "SYSLOG"
  64. fi
  65. else
  66. echo "$optval"
  67. fi
  68. }
  69. local default optval
  70. val=""
  71. config_list_foreach "$cfg" defaultnotify notifylist
  72. default="$optval"
  73. echo "NOTIFYFLAG ONLINE $(setnotify "$cfg" onlinenotify)" >> "$UPSMON_C"
  74. echo "NOTIFYFLAG ONBATT $(setnotify "$cfg" onbattnotify)" >> "$UPSMON_C"
  75. echo "NOTIFYFLAG LOWBATT $(setnotify "$cfg" lowbatnotify)" >> "$UPSMON_C"
  76. echo "NOTIFYFLAG FSD $(setnotify "$cfg" fsdnotify)" >> "$UPSMON_C"
  77. echo "NOTIFYFLAG COMMOK $(setnotify "$cfg" commoknotify)" >> "$UPSMON_C"
  78. echo "NOTIFYFLAG COMMBAD $(setnotify "$cfg" commbadnotify)" >> "$UPSMON_C"
  79. echo "NOTIFYFLAG SHUTDOWN $(setnotify "$cfg" shutdownnotify)" >> "$UPSMON_C"
  80. echo "NOTIFYFLAG REPLBATT $(setnotify "$cfg" repolbattnotify)" >> "$UPSMON_C"
  81. echo "NOTIFYFLAG NOCOMM $(setnotify "$cfg" nocommnotify)" >> "$UPSMON_C"
  82. echo "NOTIFYFLAG NOPARENT $(setnotify "$cfg" noparentnotify)" >> "$UPSMON_C"
  83. config_get val "$cfg" rbwarntime 43200
  84. echo "RBWARNTIME $val" >> "$UPSMON_C"
  85. config_get val "$cfg" nocommwarntime 300
  86. echo "NOCOMMWARNTIME $val" >> "$UPSMON_C"
  87. config_get val "$cfg" finaldelay 5
  88. echo "FINALDELAY $val" >> "$UPSMON_C"
  89. config_get val "$cfg" certpath
  90. if [ -n "$val" ]; then echo "CERTPATH $val" >> "$UPSMON_C"; fi
  91. config_get_bool val "$cfg" certverify 0
  92. if [ -n "$val" ]; then echo "CERTVERIFY $val" >> "$UPSMON_C"; fi
  93. config_get_bool val "$cfg" forcessl 0
  94. if [ -n "$val" ]; then echo "FORCESSL $val" >> "$UPSMON_C"; fi
  95. havemon=1
  96. }
  97. nut_upsmon_add() {
  98. local cfg="$1"
  99. local type="$2"
  100. local upsname
  101. local hostname
  102. local port
  103. local powervalue
  104. local username
  105. local password
  106. local system
  107. config_get upsname "$cfg" upsname
  108. config_get hostname "$cfg" hostname localhost
  109. config_get port "$cfg" port
  110. config_get powervalue "$cfg" powervalue 1
  111. config_get username "$cfg" username
  112. config_get password "$cfg" password
  113. system="$upsname@$hostname"
  114. if [ -n "$port" ]; then
  115. system="$system:$port";
  116. fi
  117. echo "MONITOR $system $powervalue $username $password $type" >> "$UPSMON_C"
  118. havems=1
  119. }
  120. build_config() {
  121. local runas
  122. mkdir -m 0750 -p "$(dirname "$UPSMON_C")"
  123. config_load nut_monitor
  124. config_foreach nut_upsmon_conf upsmon
  125. config_foreach nut_upsmon_add master master
  126. config_foreach nut_upsmon_add slave slave
  127. [ ! -s "$(cat /var/etc/nut/nut.conf)" ] && {
  128. echo "MODE=netclient" >>/var/etc/nut/nut.conf
  129. chmod 640 /var/etc/nut/nut.conf
  130. chgrp $(id -gn ${runas:-root}) /var/etc/nut/nut.conf
  131. }
  132. [ -s "$UPSMON_C" ] && chmod 640 "$UPSMON_C"
  133. [ -s "$UPSMON_C" ] && chgrp $(id -gn ${runas:-root}) "$UPSMON_C"
  134. }
  135. interface_triggers() {
  136. local action="$1"
  137. local triggerlist trigger
  138. config_get triggerlist "upsmon" triggerlist
  139. . /lib/functions/network.sh
  140. if [ -n "$triggerlist" ]; then
  141. for trigger in $triggerlist; do
  142. if [ "$action" = "add_trigger" ]; then
  143. procd_add_interface_trigger "interface.*" "$trigger" /etc/init.d/nut-monitor reload
  144. else
  145. network_is_up "$trigger" && return 0
  146. fi
  147. done
  148. else
  149. if [ "$action" = "add_trigger" ]; then
  150. procd_add_raw_trigger "interface.*.up" 2000 /etc/init.d/nut-monitor reload
  151. else
  152. ubus call network.device status | grep -q '"up": true' && return 0
  153. fi
  154. fi
  155. [ "$action" = "add_trigger" ] || return 1
  156. }
  157. start_service() {
  158. local havemon havems
  159. build_config
  160. [ "$havemon" != 1 ] && return
  161. [ "$havems" != 1 ] && return
  162. interface_triggers "check_interface_up" || return
  163. procd_open_instance "upsmon"
  164. procd_set_param respawn
  165. procd_set_param stderr 0
  166. procd_set_param stdout 1
  167. procd_set_param command /usr/sbin/upsmon -D
  168. procd_close_instance
  169. }
  170. reload_service() {
  171. if pgrep upsmon >/dev/null 2>/dev/null; then
  172. build_config
  173. /usr/sbin/upsmon -c reload
  174. else
  175. stop
  176. sleep 2
  177. start_service
  178. fi
  179. }
  180. service_triggers() {
  181. confg_load nut_monitor